58 www.fluke.com/754 Process Calibration Tools PROCESS CALIBRATION TOOLS 75X Calibrator Specifications Measure Sourcing DC voltage 0.020 % reading + 0.005 % full scale 0.01 % output + 0.005 % full scale DC current 0.01 % reading + 5 µA 0.01 % output + 0.003 mA Resistance 0.05 % reading + 50 mΩ 0.01 % output + 240 mΩ Frequency 0 to 50 KHz, ± 0.5 Hz to 1100 Hz 0 to 50 KHz, ± 0.1 Hz to 1099.9 Hz Thermocouples 0.3 °C 0.2 °C RTDs 0.3 °C 0.1 °C Pressure To 0.025 % of full scale, per pressure module specifications (Fluke 750P Series) Battery life Typically over eight hours Internal battery pack Li ion 4400 mAh Size (HxWxD) 245 mm x 136 mm x 63 mm (9.6 in x 5.4 in x 2.5 in) Weight 1.2 kg (2.7 lb) Calibration cycles One- and two-year Warranty Three-year Fluke 753 and 754 Calibrators Does the work of several tools for process systems • Calibrate temperature, pressure, voltage, current, resistance and frequency instruments • Built-in procedures for transmitters, square root transmitters, pressure and temperature switches • Simultaneously measure and source • Automatically capture calibration results • Document procedures and results to meet ISO 9000, EPA, FDA, OSHA and other requirements • Measure/simulate 13 types of thermocouples and eight RTDs 754: Get HART-ability™ The Fluke 754 offers all of the capabilities of the 753, plus the ability to calibrate, maintain and troubleshoot HART instrumentation. Integrated HART communication functions permit you to monitor, control and calibrate HART instrumentation. It handles fast pulsed instruments such as RTD transmitters and PLCs responding to pulses within 1 ms. 753: A complete documenting calibrator The 753 is a complete multifunction documenting calibrator and includes a PC interface that lets you load procedures, lists and instructions created with software—or unload data for printing, archiving, and analysis. The 753 can hold a full week of calibrations and procedures. Fluke 709/709H Precision Current Loop Calibrators • Best-in-class accuracy at 0.01 % reading • HART Communication (709H only) communicate with and test HART smart instruments • 24 V dc loop power with mA measure mode • Built in selectable 250 Ω resistor for HART communications • Valve test (source and simulate defined mA values with % keys) • Upload logged mA measurements and HART device data using the 709H with optional 709H/TRACK software HART is a registered trade mark of the HART Communications Foundation. Instrument CarePlan Ordering information Models Included accessories FLUKE-754 Documenting Process Calibrator-HART Three sets of stackable test leads, three sets of test probes with three sets of “extended tooth” alligator clips, two sets of hook clips, li-ion battery pack, battery charger, field soft case, USB communication cable, getting started guide, instruction manual on CD, traceable certificate of calibration, DPC/TRACK2 sample software that enables upload and printing of calibration records. HART communication cable (754 only) FLUKE-753 Documenting Process Calibrator FLUKE-709 Precision Current Loop Calibrator Test leads, test probes and alligator clips. Quick reference guide, traceable certificate of calibration, manual on CD. Additional hook clips (709H only) for HART communication FLUKE-709H Precision Current Loop Calibrator-HART Calibrate and document the performance of HART smart pressure transmitters with the Fluke 754 and 750 Series Pressure Modules.