Fluke Calibration Products and Services
Thermometer readouts Intrinsically safe thermometers 1551A Ex 100 Ω thin-film RTD –50 °C to 160 °C (–58 °F to 320 °F) Accuracy of ± 0.05 °C (± 0.09 °F) over full range. Intrinsically safe (ATEX and IECEx compliant). Two models to choose from (-50 °C to 160 °C or -80 °C to 300 °C) 1552A Ex 100 Ω wire-wound PRT –80 °C to 300 °C (–112 °F to 572 °F) Precision digital thermometer readouts Model Probe types Accuracy at 0 °C Features Tweener 1502A PRTs ± 0.006 °C Resolution of 0.001 °C and accuracy to match; uses ITS-90, IPTS-68, CVD, or DIN (IEC 751) conversions 1504 Thermistors ± 0.002 °C Reads thermistors from 0 to 500 KW; uses Steinhart-Hart and CVD Handheld 1523 PRTs, Thermistors, Thermocoouples ± 0.015 °C (PRTs) Battery-powered, handheld reference thermometer; INFO-CON connector reads coefficients without programming; saves 25 readings on demand; graphs trends 1524 PRTs, Thermistors, Thermocoouples ± 0.015 °C (PRTs) Handheld reference thermometer same as 1523 but with inputs for two thermometers; logs up to 15,000 readings and stores 25 more on demand Chub-E4 1529 PRTs, Thermistors, Thermocouples ± 0.006 °C (PRTs) Four channels can all be measured simultaneously; battery-powered; logs up to 8,000 readings; flexible display Super-Thermometers 1594A SPRTs, PRTs, Thermistors ± 0.00006 °C Ratio accuracy of 0.8 ppm; temperature-controlled internal reference resistors; six input channels 1595A SPRTs, PRTs, Thermistors ± 0.000015 °C Ratio accuracy of 0.2 ppm; Ratio Self-Calibration; automated zero-power measurements Multi-channel 1586A PRTs, Thermistors, Thermocouples ± 0.005 °C (PRTs) 40 channels with scan rate of 10 channels per second 1560 Accepts any combination of the modules below; all are easily added to and removed from the 1560 Black Stack base 2560 SPRTs, PRTs ± 0.005 °C 2 channels of 25W or 100W PRTs 2561 HTPRTs ± 0.013 °C 2 channels to 1200 °C 2562 PRTs ± 0.01 °C 8 channels of 2-, 3-, or 4-wire RTDs 2563 Thermistors ± 0.0013 °C 2 channels of resolution to 0.0001 °C 2564 Thermistors ± 0.0025 °C 8 channels for data acquisition 2565 Thermocouples ± 0.05 °C Reads most TC types with 0.0001 mV resolution 2566 Thermocouples ± 0.1 °C Reads any combination up to 12 channels of virtually any type of TC 2567 1000 Ω PRTs ± 0.006 °C 2 channels of high-resistance PRTs 2568 1000 Ω PRTs ± 0.01 °C 8 channels of high-resistance PRTs Thermo-hygrometer 1620A The DewK Thermo- Hygrometer Two channels measure ambient temperature to ± 0.125 °C and %RH to ±1.5 %. Onboard memory holds up to two years of time/date-stamped readings. Visual and audio alarms. Detachable sensors contain their own calibration data for easy recalibrations. Ethernet and wireless capabilities. 14 www.flukecal.com Temperature calibration
Made with FlippingBook
RkJQdWJsaXNoZXIy MzI1NjM=