Fluke Calibration Products and Services
5626/5628 5608/5609 Secondary standard PRTs 5608/5609 Secondary PRTs Very stable thermometer from –200 °C to 670 °C. • • 5608: –200 °C to 500 °C (80 mm minimum immersion) • • 5609: –200 °C to 670 °C (100 mm minimum immersion) • • Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0 5615 Secondary PRT Reference-grade platinum sensing element. • • –200 °C to 420 °C • • ± 0.012 °C accuracy at 0 °C • • Drift of ± 0.007 °C after 100 hours at max temperature 5626/5628 Secondary SPRT, PRT, Temperature Sensors High-temperature secondary standards. • • -200 °C to 661 °C • • Meets all ITS-90 requirements for resistance ratios • • Rtp drift < 20 mK after 500 hours at 661°C Thermistor standards 5640 Series Thermistor Standards Probes High accuracy temperature probes with excellent stability. • • Accuracy to ± 0.001 °C • • Affordable system accuracy to ± 0.004 °C or better • • NIST-traceable calibration included from manufacturer 5615 5640 5624 5649/5650 5622 5606 5627A 5618B 5610/5611/ 5611T/5665 Fast response PRTs 5622 Fast Response PRTs Designed for temperature measurements requiring fast response or short immersion over a wide range. • • Time constants as fast as 0.4 seconds • • Available as DIN/IEC Class A PRTs or with NVLAP-accredited calibration, lab code 200348-0 • • Small probe diameters ranging from 0.5 mm to 3.2 mm Small diameter industrial PRTs 5618B Small Diameter Industrial RTD Secondary level performance with full ITS-90 calibration. • • Small diameter sheath, 3.2 mm (0.125 in) • • Excellent stability • • Includes ITS-90 coefficients Full immersion PRTs 5606 Full Immersion PRT PRTs for laboratory freezers, autoclaves, and furnaces. • • Transition junction designed to withstand full temperature range of probe • • 5606: -200 °C to 160 °C • • Calibration accuracy of ± 0.05 °C Secondary thermistor probes 5610/5611/5611T/5665 Secondary Reference Thermistor Probes Lab-grade thermistors probes for accurate work across a narrow temperature range. • • Short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C • • Accredited NVLAP calibration optional • • Flexible Teflon and silicone coated fast-response models High temperature PRT 5624 Platinum Resistance Thermometer Precision PRT accuracy at thermocouple temperatures. • • Temperature range of 0 °C to 1000 °C • • Accuracy of ± 0.05 °C to 962 °C (includes short-term stability and calibration uncertainty) • • Long-term drift of 0.01 °C at 0 °C after 100 hours at 1000 °C Thermocouple standards 5649/5650 Type R and Type S Thermocouple Standards Eight models to fit any type R or S thermocouple applications. • • 0 °C to 1450 °C • • Two sizes available, each with or without reference junction • • Optional fixed-point calibra- tion, uncalibrated accuracy is the greater of ± 0.6 °C or ± 0.1 % of reading Precision industrial PRTs 5627A Precision Industrial PRTs Durable PRTs with temperature range to 420 °C and accuracy to 0.025 °C. • • Vibration and shock resistant • • NVLAP-accredited calibration included, lab code 200706-0 www.flukecal.com 21 Temperature calibration
Made with FlippingBook
RkJQdWJsaXNoZXIy MzI1NjM=