Process Calibration Tools Catalog EN

5608/5609/5609-BND 5627A 5615 21 Temperature Calibration Precision PRTs High accuracy reference temperature measurements in temperature sources on the bench or in the field. 5627A Precision Industrial PRT • Vibration and shock resistant • Calibration accuracy of ± 0.046 °C at 0 °C • Available with a 90° bend • NVLAP-accredited calibration included, lab code 200706-0 www.flukecal.eu/5627 5615 Secondary Reference Temperature Standards • –200 °C to 420 °C • Calibrated accuracy ± 0.010 °C at 0 °C • NVLAP-accredited calibration included, lab code 200706-0 www.flukecal.eu/5615 5608/5609/5609-BND Secondary Reference PRTs Drift rate of ± 0.01 °C at 0 °C after 100 hours at max temperature. • 5608: –200 °C to 500 °C (80 mm minimum immersion) • 5609: –200 °C to 670 °C (100 mm minimum immersion) • Comes with certificate of compliance - optional NVLAP-accredited calibration www.flukecal.eu/5608 5622 Fast Response PRTs • Time constants as fast as 0.4 seconds • Small probe diameters ranging from 0.5 mm to 3.2 mm (four models available) • Available as DIN/IEC Class A PRTs or with optional NVLAP-accredited calibration, lab code 200348-0 www.flukecal.eu/5622 5626/5628 Secondary SPRT, PRT, Temperature Sensors • Range to 661°C • Meets all ITS-90 requirements for resistance ratios • Rtp drift < 20 mK after 500 hours at 661°C • Calibrated accuracy of ± 0.006 °C at 0 °C • NVLAP accredited fixed point calibration www.flukecal.eu/5622 5618B Small Diameter Industrial RTD Fast response for time-dependent measurements. • Small diameter sheath, 3.2 mm (0.125 in) • Excellent stability • Includes ITS-90 coefficients • NVLAP accredited calibration, lab code 200706-0 www.flukecal.eu/5618B 5606 Full Immersion PRT Fully immerse PRT transition junction inside freezers or furnaces. • Transition junction designed to withstand full temperature range of probe • -200 °C to 160 °C • Calibration accuracy of ± 0.05 °C (full range) • Optional NVLAP accredited calibration www.flukecal.eu/5606 Thermistors Providing accurate and rugged temperature measurements from 0 °C to 100 °C. 5610/5611/5611T Secondary Reference Thermistor Probes Economical lab-grade therm- istor probes with low drift susceptibility. • Short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C • 5610: 3.2 mm diameter stain- less steel sheathed thermistor • 5611: 1.5 mm diameter (tip) silicone coated thermistor • 5611T: 3 mm diameter (tip) PTFE encapsulated thermistor www.flukecal.eu/5610 5610 5622 5611T 5606 5611 5626/5628 5618B

RkJQdWJsaXNoZXIy MzI1NjM=