Figure 1.
G703 - E1 template
ApplicationNote
From the Fluke Digital Library @ www.fluke.com/library
TheG.703 standard
G.703 is a standard origi-
nally introduced for voice and
data transmission over digital
networks. It is an ITU recom-
mendation (formerly CCITT)
that’s associatedwith the PCM
standard. Analog-voice to digital-
data conversion according to
PCM requires a bandwidth of
64 kb/s (±100 ppm), resulting in
the basic unit forG.703. Through
multiplexing this results in a T1
of 1.544Mb/s and E1 of
2.048Mb/s.
The electrical characteristics
of the network interfaces are
described in recommendation
G.703. The signal limits for a
2.048Mb/s signal are shown in
Figure 1.
Multiple-channel
testing using two
differentmasks
A balun is used between the
patch panel and a coaxial
transmission line tomatch the
impedance of the 120
Ω
sym-
metrical line to a 75
Ω
coaxial
line. The input and output of the
balun each has its specificmask.
The ScopeMeter 190 Series II
portable oscilloscopes can simul-
taneously perform a pass/fail test
at the input and output of the
balunwith differentmasks.
The floating and isolated
inputs of the Fluke ScopeMeter
190 Series II test toolsmake
thesemeasurements pos-
siblewithout the risk ofmaking
unwanted groundings.Moreover,
the high impedance probes allow
for directmeasurementswithout
loading the line andwithout the
need for an external differential
probe.
Testing telecommunication
equipment using Pass/Fail
mask testing with a Fluke
ScopeMeter
®
190 Series II
Editing the pass/fail
templates
With FlukeViewwe can export
awaveform into a spreadsheet
and a custom template can be
created by editing awaveform
using Excel.
A reference template for
pass/fail testing can be cre-
ated by savingwaveforms from
FlukeView in .csv format and
editing thewaveform using, for
Figure 2.
ISDN30 network
ISDN30
Patch
Panel
Balun
SDH
Distr.
2Mb/s
120Ω
2Mb/s
120Ω
2Mb/s
75Ω
Telephone
Exchange
Nowadays digital communication systems such as Synchronous
DigitalHierarchy (SDH) in Europe and the SynchronousOptical
Network (SONET) inNorthAmerica require standard testmethods.
The electrical signals are tested against the standard ITU pulse
masks. The Fluke ScopeMeter 190 Series II portable oscilloscope
offers a standard pass/fail function that can be used to perform
these tests. The instrument is capable of storing up to 100 “fails”
for further analysis.
ApplicationNote
Demystifying
drive anomalies
using theFluke 190Series II2-Channel
ScopeMeter
®
portableoscilloscope
From the Fluke Digital Library @ www.fluke.com/library
Vogel, anHVAC technician,
becomes energizedwhen dis-
cussing the return on investment
in his handheld ScopeMeter
®
Test Tool. “Out at one large site,
wherewemonitor and trouble-
shoot variable frequency drives
(VFDs), component-level repair
can oftenmean the differece
between a $20 repair part and
a $100,000 repair bill. I know
firsthand, becausewe recently
documented that very scenario.”
On large VFDs, Vogel uses his
ScopeMeter portable oscilloscope
to uncover capacitance problems,
transistor firingmishaps, and
even bleed-throughs on a gate.
“Of course, a transistor is basi-
cally a lightning-fast switch,”
he says. “It switches back and
forth
en and closed,
and itcan sometimes start to
break down.When that happens,
motorswill start doingweird
things. For example, at load
stagewe’ll actually see
themotor banging back and
forth as if it is not surewhich
way to turn.”
Seeing is believing?More aptly, seeing is
understanding.
If anyone canwring every last ounce of functionality out
of a piece of electronic test equipment, it’sChris Vogel.
At SiemensBuilding Technologies, Vogel has hiswork cut
out for him keepingHVAC systems running for the com-
pany’s large commercial customers in Florida’s tropical
weather,which ismarked by seemingly nonstop 90 °F
temperatures and 95% humidity levels.And that’s just
one of the challenges faced by technicians at Siemens
Building Technologies,which plays amore sweeping role
in its customers’ success: ensuring energy efficiency,
comfort, protection against unauthorized access, and
fire safety year-round for every building or office tower
entrusted to it by customers.
Storing a slice of time
It’s important, says Vogel,
that the technician be able to
characterize VFD problems by
capturing awaveform from the
offending drive.His premise: A
signal ismuchmore tellingwhen
presented in awaveform view
than in a single, static volt-
age reading. The signal has a
shape and value thatmay look
right at a glance, but could just
as easily have a distortion or
rough “edge,” or amomentary
spike almost too short to be
seen. Either problem, or a host
of other signal anomalies,would
be indistinguishablewith just a
numeric reading of the signal.
“The scope allowsme to
record information, and from a
number of sources—sinewaves
on the inputs and outputs of
VFDs, current and voltage—and,
for thatmatter,make compari-
sons of current and voltage so
that I can derive a power factor
for the circuit.”
Operator:
CrisVogel,HVAC
Technician forSiemensBuilding
Technologies
Testing
Functions
Case
Study
Measuring tools:
190 Series II
2-Channel
ScopeMeter
®
TestTool
Measurements:
Currentand voltage
waveform analysis, power factor
Connect the ScopeMeter
test tool and view the
result: the start of every
measurement
It frequently happens that service
engineers have to spend a lot of
time adjusting theirmeasuring
device such as a portabl oscil-
loscope for an optimal setting.
Valuable time is spent completing
this set up, and ideally, this could
be done automatically.
With the introduction of the
new ScopeMeter 190 Series II,
Fluke has revamped its unique
feature, Connect andView.
Scope users know how dif-
ficult triggering can be.Wrong
settings show unstable and
somtimswrong results. Fluke’s
unique Connect andView
recognizes signalpatterns, and
automatically sets up correct
riggering, attenuator and time
base settings. Switcing on the
ScopeMeter portable oscilloscope
to display correct signal patterns
only takes a couple of seconds,
and this is exactlywhat an
operatorwants.
Settings regarding
amplitude,
timebase,
triggering,
etc.
are automatically detected and
adjusted, followed by display-
ing the signal in the correct atio
with respect to the horizontal
and vertical axis.At least 1.5
t 4 perids of the signal are
measured before the pattern is
shown.
Connect andView provides
a stable, reliable and repeat-
able display of virtually any
signal, includingmotor drive and
controlsignals,without touch-
ing a button. Signal changs are
instantly recognized and settings
adjusted for, once again, a stable
display. This is all done auto-
matically, butmanual overruling
is still possible. Ifmanual over-
ruling is needed, the ScopeMeter
190Serieswill switch frm auto-
matic to 1/2 automatic,whch is
visible on the display.
Figure 1 gives an example of
the different ypes ofwaveforms
which can de detected by
Connect& View. If required the
criteria for best settings can be
optimizd by switching on one or
all of the following options:
Automatic trigger
ApplicationNote
From the Fluke Digital Library @
Figure1.
AC/DC coupling
Glitch detect
Figure 2 shows the different
settings.
87
ScopeMeter
®
Portable
Oscilloscopes 190 Series II
190 Series II models with isolated dual input
scope and dedicated digital multimeter.
Conveniently switch from waveform analysis
to precise multimeter measurements using
the built in 5000 count digital multimeter.
Measurement functions include Vdc, Vac,
Vac+dc, resistance, continuity and diode test.
Measure current and temperature using suitable
shunt, probe or adapter with wide range of
scaling factors.
Scope users know how frustrating it is to see
a one-time anomaly flash by, never to be seen
again. Not with the ScopeMeter 190-II! Now you
can look back in time with the touch of a button.
In normal use, the instrument continuously
memorizes the most recent 100 screens. At any
moment in time, you can ‘freeze’ these latest
screens and scroll through them picture-by-
picture or replay them as a ‘live’ animation.
Cursors and zoom can be used for further analysis. You can even use the advanced
trigger capabilities to capture up to 100 specific events. Two sets of 100 screens with
individual time stamps can be stored for later recall or download to a PC.
The built in multimeter provides
convenient precision measurements.
Built-in 5000 count digital multimeter
(2 channels)
Automatic capture and replay on 100 screens
A range of application notes is available.
See the Fluke website.
Included Accessories
Fluke 190 Series II 4-channel instruments include a set
of four probes, hanging strap, handstrap, USB cable with
mini-B connector, double capacity Li-ion battery BP291,
battery charger/power adapter BC190, a FlukeView demo
package and users manuals on CD-ROM.
The 2-channel models come with two probes plus a set
of TL175 test leads and a single capacity battery BP290.
The 190-502 also includes 2 pcs TRM50 coaxial
feedthrough terminator and has a double capacity battery
BP291.
Ordering Information
Fluke-190-502/S Color ScopeMeter (500 MHz,
2 channel), with SCC290-kit
Fluke-190-502
Color ScopeMeter (500 MHz, 2 channel)
Fluke-190-204/S Color ScopeMeter (200 MHz,
4 channel), with SCC290-kit
Fluke-190-204
Color ScopeMeter (200 MHz, 4 channel)
Fluke-190-202/S Color ScopeMeter (200 MHz,
2 channel), with SCC290-kit
Fluke-190-202
Color ScopeMeter (200 MHz, 2 channel)
Fluke-190-104/S Color ScopeMeter (100 MHz,
4 channel), with SCC290-kit
Fluke-190-104
Color ScopeMeter (100 MHz, 4 channel)
Fluke-190-062/S Color ScopeMeter (60 MHz,
2 channel), with SCC290-kit
Fluke-190-062
Color ScopeMeter (60 MHz, 2 channel)
Fluke-190-102/S Color ScopeMeter (100 MHz,
2 channel), with SCC290-kit
Fluke-190-102
Color ScopeMeter (100 MHz, 2 channel)
See dynamic signal behavior instantly
The digital Persistence mode helps to find anomalies and to analyze complex
dynamic signals by showing the waveforms amplitude distribution over time using
multiple intensity levels and user selectable decay time – it’s as if you’re looking at
the display of an analog, real time oscilloscope! A fast display update rate reveals
signal changes instantaneously, useful for instance when making adjustments to a
system under test.
For all optional accessories for the Fluke 190 Series, see page 89