Top related product |
Top related product |
Best match |
||||
---|---|---|---|---|---|---|
Fluke 323 |
Fluke 324 |
Fluke 325 |
||||
Measurements | ||||||
AC current | 400 A | 400 A | 400 A | |||
DC current | 400 A | |||||
AC voltage | 600 V | 600 V | 600 V | |||
DC voltage | 600 V | 600 V | 600 V | |||
True-rms | • | • | • | |||
Min/Max/Avg | ||||||
Resistance | • | • | • | |||
Frequency | • | |||||
Continuity | • | • | • | |||
Measurement logging | ||||||
AC + DC voltage | ||||||
AC + DC current | ||||||
Temperature | • | • | ||||
Capacitance | • | • | ||||
Fluke Connect | ||||||
Compatible with Fluke Connect® app | ||||||
Compatible with Fluke Connect® Assets software | ||||||
Special features | ||||||
Inrush current mode | ||||||
Low Pass filter for VFD's | ||||||
18-inch (45 .7 cm) iFlex Flexible Current Probe | ||||||
10-inch (25 .4 cm) iFlex Flexible Current Probe | ||||||
Remote display | ||||||
Wireless | ||||||
Display | ||||||
Display hold | • | • | • | |||
Backlight | • | • | ||||
Graphing display | ||||||
Specifications | ||||||
Jaw opening | 30 mm (1.18 in) | 30 mm (1.18 in) | 30 mm (1.18 in) | |||
Max wire size | 300 mm² | 300 mm² | 300 mm² | |||
Current range AC rms | 0 to 400 .0 A | 0 to 40 .00 A/ 400 .0 A | 0 to 40 .00 A/ 400 .0 A | |||
Accuracy AC current (50/60 Hz) | 2% ± 5 counts |
2% ± 5 counts |
2% ± 5 counts |
|||
AC Response | True-rms | True-rms | True-rms | |||
Current range DC | 0 to 40 .00 A/ 400 .0 A | |||||
Accuracy DC current | 2% ± 5 counts |
|||||
Voltage range AC | 0 to 600 .0 V | 0 to 600.0 V | 0 to 600 .0 V | |||
Accuracy AC voltage | 1.5% ± 5 counts |
1.5% ± 5 counts |
1.5% ± 5 counts |
|||
Voltage range DC | 0 to 600 .0 V | 0 to 600 .0 V | 0 to 600 .0 V | |||
Accuracy DC voltage | 1.0% ± 5 counts |
1.0% ± 5 counts |
1.0% ± 5 counts |
|||
Resistance range | 0 to 4000 Ω | 0 to 4000 Ω | 0 to 40 kΩ | |||
Frequency measurement range | 5 Hz to 500 Hz | |||||
Unit power | ||||||
Auto off | • | • | • | |||
Warranty and safety | ||||||
Warranty (years) | 2 | 2 | 2 | |||
Safety rating (EN 61010) | CAT IV 300 V, CAT III 600 V | CAT IV 300 V, CAT III 600 V | CAT IV 300 V, CAT III 600 V | |||
Downloads | ||||||
Datasheet | Download | Download | Download | |||
True-rms measurements and optimized ergonomics make the 320 Series Clamp Meters the best general troubleshooting tools for commercial and residential electricians. The 323, 324 and 325 are designed to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small and rugged clamp meters are ideally suited for current measurements up to 400 A in tight cable compartments.
The Fluke 324 model also includes temperature and capacitance measurement capabilities to create one solid troubleshooting tool.