Measurements | ||||||||
AC current | 600 A | 600 A | 999.9 A | 999.9 A | ||||
DC current | 600 A | 600 A | 999.9 A | 999.9 A | ||||
AC voltage | 600 V | 600 V | 1000 V | 1000 V | ||||
DC voltage | 600 V | 600 V | 1000 V | 1000 V | ||||
True-rms | • | • | • | • | ||||
Min/Max/Avg | • | • | • | • | ||||
Resistance | • | • | • | • | ||||
Frequency | • | • | • | |||||
Continuity | • | • | • | • | ||||
Measurement logging | • | • | ||||||
AC + DC voltage | ||||||||
AC + DC current | ||||||||
Temperature | ||||||||
Capacitance | • | • | • | |||||
Fluke Connect | ||||||||
Compatible with Fluke Connect® app | • | • | • | |||||
Compatible with Fluke Connect® Assets software | • | • | • | |||||
Special features | ||||||||
Inrush current mode | • | • | • | • | ||||
Low Pass filter for VFD's | • | • | • | |||||
18-inch (45 .7 cm) iFlex Flexible Current Probe | Optional | Optional | Included | Included | ||||
10-inch (25 .4 cm) iFlex Flexible Current Probe | Optional | Optional | Optional | Optional | ||||
Remote display | in phone app | in phone app | in phone app | • | ||||
Wireless | • | • | • | |||||
Display | ||||||||
Display hold | • | • | • | • | ||||
Backlight | • | • | • | • | ||||
Graphing display | in phone app | in phone app | in phone app | |||||
Specifications | ||||||||
Jaw opening | 34 mm (1.33 in) | 34 mm (1.33 in) | 34 mm (1.33 in) | 34 mm (1.33 in) | ||||
Max wire size | 400 mm² | 400 mm² | 400 mm² | 400 mm² | ||||
Current range AC rms | 0 to 600.0 A (2500 A with iFlex) | 0 to 600.0 A (2500 A with iFlex) | 0 to 999.9 A (2500 A with iFlex) | 0 to 999.9 A (2500 A with iFlex) | ||||
Accuracy AC current (50/60 Hz) | 2%
± 5 counts |
2%
± 5 counts |
2%
± 5 counts |
2%
± 5 counts |
||||
AC Response | True-rms | True-rms | True-rms | True-rms | ||||
Current range DC | 0 to 600.0 A | 0 to 600.0 A | 0 to 999.9 A | 0 to 999.9 A | ||||
Accuracy DC current | 2%
± 5 counts |
2%
± 5 counts |
2%
± 5 counts |
2%
± 5 counts |
||||
Voltage range AC | 0 to 1000 V | 0 to 1000 V | 0 to 1000 V | 0 to 1000 V | ||||
Accuracy AC voltage | 1.5%
± 5 counts |
1.5%
± 5 counts |
1.5%
± 5 counts |
1.5%
± 5 counts |
||||
Voltage range DC | 0 to 1000 V | 0 to 1000 V | 0 to 1000 V | 0 to 1000 V | ||||
Accuracy DC voltage | 1%
± 5 counts |
1%
± 5 counts |
1%
± 5 counts |
1%
± 5 counts |
||||
Resistance range | 0 to 6000 Ω | 0 to 6000 Ω | 0 to 60 kΩ | 0 to 60 kΩ | ||||
Frequency measurement range | 500 Hz | 500 Hz | 500 Hz | |||||
Unit power | ||||||||
Auto off | • | • | • | • | ||||
Warranty and safety | ||||||||
Warranty (years) | 3 | 3 | 3 | 3 | ||||
Safety rating (EN 61010) | CAT III 1000 V,
CAT IV 600 V |
CAT III 1000 V,
CAT IV 600 V |
CAT III 1000 V,
CAT IV 600 V |
CAT III 1000 V,
CAT IV 600 V |
||||
Downloads | ||||||||