It looks like you’re in need of a general purpose Clamp Meter

Best match

Fluke 375 FC

Download datasheet
Buy Now
 

Top related product

 

Best match

 

Top related product

 

Top related product

 
 
Fluke 374 FC
 
Fluke 375 FC
 
Fluke 376 FC
 
Fluke 381
 
         
Buy Now  
 
 
 
Measurements                
AC current 600 A   600 A   999.9 A   999.9 A  
DC current 600 A   600 A   999.9 A   999.9 A  
AC voltage 600 V   600 V   1000 V   1000 V  
DC voltage 600 V   600 V   1000 V   1000 V  
True-rms •   •   •   •  
Min/Max/Avg •   •   •   •  
Resistance •   •   •   •  
Frequency     •   •   •  
Continuity •   •   •   •  
Measurement logging     •   •      
AC + DC voltage                
AC + DC current                
Temperature                
Capacitance •   •   •      
Fluke Connect                
Compatible with Fluke Connect® app •   •   •      
Compatible with Fluke Connect® Assets software •   •   •      
Special features            
Inrush current mode •   •   •   •  
Low Pass filter for VFD's     •   •   •  
18-inch (45 .7 cm) iFlex Flexible Current Probe Optional   Optional   Included   Included  
10-inch (25 .4 cm) iFlex Flexible Current Probe Optional   Optional   Optional   Optional  
Remote display in phone app   in phone app   in phone app   •  
Wireless •   •   •      
Display                
Display hold •   •   •   •  
Backlight •   •   •   •  
Graphing display in phone app   in phone app   in phone app      
Specifications                
Jaw opening 34 mm (1.33 in)   34 mm (1.33 in)   34 mm (1.33 in)   34 mm (1.33 in)  
Max wire size 400 mm²   400 mm²   400 mm²   400 mm²  
Current range AC rms 0 to 600.0 A (2500 A with iFlex)   0 to 600.0 A (2500 A with iFlex)   0 to 999.9 A (2500 A with iFlex)   0 to 999.9 A (2500 A with iFlex)  
Accuracy AC current (50/60 Hz) 2%
± 5 counts
  2%
± 5 counts
  2%
± 5 counts
  2%
± 5 counts
 
AC Response True-rms   True-rms   True-rms   True-rms  
Current range DC 0 to 600.0 A   0 to 600.0 A   0 to 999.9 A   0 to 999.9 A  
Accuracy DC current 2%
± 5 counts
  2%
± 5 counts
  2%
± 5 counts
  2%
± 5 counts
 
Voltage range AC 0 to 1000 V   0 to 1000 V   0 to 1000 V   0 to 1000 V  
Accuracy AC voltage 1.5%
± 5 counts
  1.5%
± 5 counts
  1.5%
± 5 counts
  1.5%
± 5 counts
 
Voltage range DC 0 to 1000 V   0 to 1000 V   0 to 1000 V   0 to 1000 V  
Accuracy DC voltage 1%
± 5 counts
  1%
± 5 counts
  1%
± 5 counts
  1%
± 5 counts
 
Resistance range 0 to 6000 Ω   0 to 6000 Ω   0 to 60 kΩ   0 to 60 kΩ  
Frequency measurement range     500 Hz   500 Hz   500 Hz  
Unit power                
Auto off •   •   •   •  
Warranty and safety                
Warranty (years) 3   3   3   3  
Safety rating (EN 61010) CAT III 1000 V,
CAT IV 600 V
  CAT III 1000 V,
CAT IV 600 V
  CAT III 1000 V,
CAT IV 600 V
  CAT III 1000 V,
CAT IV 600 V
 
Downloads                
Datasheet Download   Download   Download   Download  
               

Fluke 375 FC True-rms AC/DC Clamp Meter

The Fluke 375 FC is a high-performance clamp meter with wireless communication and logging capabilities.

Because the Fluke 375 FC is part of the Fluke Connect family of wireless test tools, you can:

  • Log and trend measurements to pinpoint intermittent faults
  • Transmit results wirelessly via Fluke Connect® Measurements app
  • Create and send reports right from the field
  • Stay safely away from the arc flash zone through Bluetooth connectivity to Apple
    and Android devices