21
3000 FC
Wireless Digital Multimeter
See it. Save it. Share it.
The Fluke 3000 FC True-RMS Wireless
Multimeter and Fluke Connect wireless
test tools put tools, not your body,
near live electrical panels. It’s simple.
Just de-energize the cabinet, open the
panel while wearing PPE and connect
the remote modules, whether they are
voltage modules, current clamps, flexible
current loops or thermometers. Then
read the results on the 3000 FC Wireless
Multimeter from a safe distance. You can
display the meter measurement, plus
readings from up to 3 wireless modules,
while reducing the risk of arc flash by
separating yourself from hazardous
measurement situations.
Better still, the Fluke 3000 FC Series
Wireless Multimeter can send
measurement data to your smartphone,
so you can save and share measurements
from the field with your team anytime,
from anywhere.
Other capabilities of Fluke Connect and
the FC 3000 Multimeter.
• Connect to your PC with USB dongle
(optional) for analysis and diagnosis
in detail.
• Perform for analysis with your
smarthphone and the FC App and
share the results using Fluke Cloud™
storage and ShareLive™ video call. View
data or graphs to get input from team
members.
The Fluke 3000 FC Series Wireless
Multimeter with the Fluke Connect™
app has all the essentials for convenient
test and measurement troubleshooting.
• AC and DC voltage measurements to
1000V
• AC and DC current with 0.01 mA
resolution
• Continuity, resistance, diode
test, capacitance and frequency
measurements
• MIN/MAX Recording
• CAT III 1000 V, Cat IV 600 V; IP54
Functions
Range and resolution
Basic accuracy
AC voltage
600.0 mV, 6.000 V, 60.00 V, 600.0 V,
1000V
1.0 % + 3
DC voltage
600.0 mV, 6.000 V, 60.00 V, 600.0 V,
1000V
0.09 % + 2
Continuity
Meter beeps at < 25 Ω, beeper
detects opens or shorts of 250 μs
or longer
Resistance
600 Ω, 600.0 Ω, 6.000 kΩ, 60.00 kΩ,
60.00 kΩ, 600.0 kΩ, 50.00 MΩ
0.5 % + 1
Diode test
2.000 V
1 % + 2
Capacitance
1000 nF, 10.00 μF, 100.0 μF, 9999 μF1 1.2 % + 2
mA AC (45 Hz to 1 kHz)
60.00 mA, 400.0 mA3
1.5 % + 3
mA DC2
60.00 mA, 400.0 mA3
0.5 % + 3
Frequency
0.01 Hz, 0.1 Hz, 0.001 kHz, 0.01 kHz 0.1 % + 1
1 In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
2 Input burden voltage (typical): 400 mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.
For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative
humidity at 0 % to 90 %.Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).
Specifications
Recommended Accessories
Included Accessories
TL175 Test Leads, AC175 Alligator Clips,
manual information pack.
Ordering Information
Fluke 3000FC FC Wireless Digital Multimeter
For more information on Fluke Connect,
see pages 13-18.
PC adapter