Process Calibration Tools Catalog EN
7 Electrical, Multifunction, and mA Loop Calibration mA Loop Calibrators Fluke loop calibrators are ideal for a wide variety of calibration applications from 4 to 20 mA. 705 Loop Calibrator A cost-effective, integrated solu- tion for calibration, repair and maintenance of current loops. • mA sourcing, simulation and measurement • Simultaneous mA and % of span display • 24 V loop supply with mA measure • 0 V dc to 28 V dc measurement to check loop voltage • NIST traceable calibration www.fluke.com/705 707 Loop Calibrator A high performance, extremely fast and easy-to-use solution for calibration, repair and mainte- nance of current loops. • mA sourcing, simulation and measurement • 24 V loop supply with mA measure, including 250 Ω HART resistor • 0 V dc to 28 V dc measurement to check loop voltage • NIST traceable calibration www.fluke.com/707 707EX IS Loop Calibrator An intrinsically safe option for use in explosion endangered areas— certified in accordance with the ATEX directive (Ex II 2 G Ex ia IIC T4) in Zones 1 and 2. • 1 µA resolution for mA source, simulate and measure • Measures V dc to 28 V • 0-20 mA or 4-20 mA default startup modes • HART ® compatible resistance is connected in series with the loop supply for compatibility with HART communicators • NIST traceable calibration www.fluke.com/707EX 707 709 705 709 Precision Loop Calibrator Reduces the time it takes to measure or source voltage or current and power up a loop. • Best-in-class accuracy at 0.01% reading • Small rugged design operates on six standard AAA batteries • Intuitive user interface with Quick-Set knob for fast setup, easy use • Built-in selectable 250 Ω resistor for HART communication • 24 V dc loop power with mA Measure Mode (-25% to 125%) • Resolution of 1 µA on mA ranges and 1 mV on voltages ranges • NIST traceable calibration www.fluke.com/709 709H Precision Loop Calibrator with HART Communications/Diagnostics Designed to save time and produce high-quality results • HART Communication built in for easy HART device maintenance • Best-in-class accuracy at 0.01% reading • Small rugged design operates on six standard AAA batteries • Intuitive user interface with Quick-Set knob for fast setup, easy use • Built-in selectable 250 Ω resistor for HART communication • 24 V dc loop power with mA Measure Mode (-25% to 125%) • Resolution of 1 µA on mA ranges and 1 mV on voltage ranges • NIST traceable calibration www.fluke.com/709H 707EX 709H
RkJQdWJsaXNoZXIy MzI1NjM=