78
General Specifications
Performance Series
Ti125
Ti110
Ti105
Ti100
Ti95
Ti90
Key features
IFOV (spatial resolution)
3.39 mRad
5.6 mRad
Resolution
160x120
(19,200 pixels)
80x80
(6,400 pixels)
80x60
(4,800 pixels)
Field of view
22.5 °H x 31 °V
26 °H x 26 °V
19.5 °H x 26 °V
Wireless connectivity
Yes
Fluke Connect™ App compatible
Yes, with included wireless SD card (where available)
IR-Fusion
®
technology
Picture-In-Picture (PIP)
Yes
PIP
(1.2 m to 4.6 m)
—
PIP
(46 cm) and beyond)
—
Focus system
IR-OptiFlex™ focus system
15 cm and beyond
Fixed focus
122 cm (48 in) and beyond
Fixed focus
46 cm (18 in) and beyond
Ruggedized display
3.5 inch diagonal (portrait format)
Thermal sensitivity (NETD)
≤ 0.10 °C at 30 °C target temp (100 mK)
≤ 0.15 °C at
30 °C target temp
(150 mK)
Temperature measurement range
(not calibrated below -10 °C)
-20 °C to +350 °C
-20 °C to +250 °C
Level and span
Smooth auto and manual scaling
Minimum span (in manual mode)
2.5 °C
Minimum span (in auto mode)
5 °C
Built-in digital camera (visible light)
2 megapixel industrial performance
None - IR Only
2 megapixel industrial performance
Frame rate
9 Hz or 30 Hz versions
9 Hz only
Data storage and image capture
Extensive SD memory system
Removable 8 Gb SD memory card and 8 Gb wireless SD card (where available); direct download via USB-to-PC connection
Image capture, review, save mechanism
One-handed image capture, review, and save capability
File formats image
Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); No analysis software required for non-radiometric
(.bmp, .jpg) files
Memory review
Thumbnail view navigation and review selection
Export file formats with
SmartView
®
software
BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF
Voice annotation
60 seconds maximum recording time per
image; reviewable playback on camera
—
Battery
Batteries
(field-replaceable, rechargeable)
Two lithium ion
smart battery packs
with five-segment
LED display to show
charge level
One lithium ion smart battery pack with five-segment LED display to show charge level
Battery life
Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage)
Battery charge time
2.5 hours to full charge
Battery
AC battery charging system
Two-bay ac battery
charger (110 V AC to
220 V AC, 50/60 Hz)
(included), or in-
imager charging.
AC mains adapters
included in 9 Hz ver-
sions. Optional 12 V
automotive charging
adapter
In-imager charging. AC mains adapters included in 9 Hz versions. Optional two-bay ac battery charger
(110 V AC to 220 V AC, 50/60 Hz) or optional 12 V automotive charging adapter.
Temperature measurement
Accuracy
± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
On-screen emissivity correction
Yes (both number and table)
On-screen reflected background
temperature compensation
Yes
On-screen transmission correction
Yes
—
Color Palettes
Standard Palettes
8: Ironbow, Blue-Red, High-Contrast,
Amber, Amber Inverted, Hot Metal, Grayscale,
Grayscale Inverted
7: Ironbow, Blue-Red,
High-Contrast, Amber,
Hot Metal, Grayscale,
Grayscale Inverted
4: Ironbow, Blue-Red,
Amber, Grayscale
6: Ironbow, Blue-Red,
High-Contrast, Amber,
Hot Metal, Grayscale
3: Ironbow,
Blue-Red, Grayscale
General specifications
Infrared spectral band
7.5 µm to 14 µm (long wave)
9 µm to 15 µm (long wave)
Operating - / Storage temperature
-10 °C to +50 °C / -20 °C to +50 °C
Center-point temperature measurement
Yes
Spot markers
User selectable hot
spot and cold spot
markers, 3 user defi-
nable spot markers on
camera and in Smart-
view
®
Software
3 user definable spot markers on camera and in
Smartview
®
Software
—
Hot and cold spot
markers
—
Center box (MIN-MAX-AVG)
Expandable-contractable measurement box
with MIN-MAX-AVG temp
Fixed-size measure-
ment box with
MIN-MAX-AVG temp
Drop
Engineered to withstand 2 meter (6.5 feet) drop
Size (H x W x L) / Weight (battery included)
28.4 cm x 8.6 cm x 13.5 cm / 0.726 kg
Enclosure rating
IP54 (protected against dust, limited ingress; protection against water spray from all directions)
Warranty
Two-years (standard), extended warranties are available
Recommended calibration cycle
Two-years (assumes normal operation and normal aging)
Supported Languages
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish,
Swedish, Traditional Chinese, and Turkish