Background Image
Previous Page  82 / 164 Next Page
Information
Show Menu
Previous Page 82 / 164 Next Page
Page Background

78

General Specifications

Performance Series

Ti125

Ti110

Ti105

Ti100

Ti95

Ti90

Key features

IFOV (spatial resolution)

3.39 mRad

5.6 mRad

Resolution

160x120

(19,200 pixels)

80x80

(6,400 pixels)

80x60

(4,800 pixels)

Field of view

22.5 °H x 31 °V

26 °H x 26 °V

19.5 °H x 26 °V

Wireless connectivity

Yes

Fluke Connect™ App compatible

Yes, with included wireless SD card (where available)

IR-Fusion

®

technology

Picture-In-Picture (PIP)

Yes

PIP

(1.2 m to 4.6 m)

PIP

(46 cm) and beyond)

Focus system

IR-OptiFlex™ focus system

15 cm and beyond

Fixed focus

122 cm (48 in) and beyond

Fixed focus

46 cm (18 in) and beyond

Ruggedized display

3.5 inch diagonal (portrait format)

Thermal sensitivity (NETD)

≤ 0.10 °C at 30 °C target temp (100 mK)

≤ 0.15 °C at

30 °C target temp

(150 mK)

Temperature measurement range

(not calibrated below -10 °C)

-20 °C to +350 °C

-20 °C to +250 °C

Level and span

Smooth auto and manual scaling

Minimum span (in manual mode)

2.5 °C

Minimum span (in auto mode)

5 °C

Built-in digital camera (visible light)

2 megapixel industrial performance

None - IR Only

2 megapixel industrial performance

Frame rate

9 Hz or 30 Hz versions

9 Hz only

Data storage and image capture

Extensive SD memory system

Removable 8 Gb SD memory card and 8 Gb wireless SD card (where available); direct download via USB-to-PC connection

Image capture, review, save mechanism

One-handed image capture, review, and save capability

File formats image

Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2); No analysis software required for non-radiometric

(.bmp, .jpg) files

Memory review

Thumbnail view navigation and review selection

Export file formats with

SmartView

®

software

BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF

Voice annotation

60 seconds maximum recording time per

image; reviewable playback on camera

Battery

Batteries

(field-replaceable, rechargeable)

Two lithium ion

smart battery packs

with five-segment

LED display to show

charge level

One lithium ion smart battery pack with five-segment LED display to show charge level

Battery life

Four+ hours continuous use per battery pack (assumes 50 % brightness of LCD and average usage)

Battery charge time

2.5 hours to full charge

Battery

AC battery charging system

Two-bay ac battery

charger (110 V AC to

220 V AC, 50/60 Hz)

(included), or in-

imager charging.

AC mains adapters

included in 9 Hz ver-

sions. Optional 12 V

automotive charging

adapter

In-imager charging. AC mains adapters included in 9 Hz versions. Optional two-bay ac battery charger

(110 V AC to 220 V AC, 50/60 Hz) or optional 12 V automotive charging adapter.

Temperature measurement

Accuracy

± 2 °C or 2 % (at 25 °C nominal, whichever is greater)

On-screen emissivity correction

Yes (both number and table)

On-screen reflected background

temperature compensation

Yes

On-screen transmission correction

Yes

Color Palettes

Standard Palettes

8: Ironbow, Blue-Red, High-Contrast,

Amber, Amber Inverted, Hot Metal, Grayscale,

Grayscale Inverted

7: Ironbow, Blue-Red,

High-Contrast, Amber,

Hot Metal, Grayscale,

Grayscale Inverted

4: Ironbow, Blue-Red,

Amber, Grayscale

6: Ironbow, Blue-Red,

High-Contrast, Amber,

Hot Metal, Grayscale

3: Ironbow,

Blue-Red, Grayscale

General specifications

Infrared spectral band

7.5 µm to 14 µm (long wave)

9 µm to 15 µm (long wave)

Operating - / Storage temperature

-10 °C to +50 °C / -20 °C to +50 °C

Center-point temperature measurement

Yes

Spot markers

User selectable hot

spot and cold spot

markers, 3 user defi-

nable spot markers on

camera and in Smart-

view

®

Software

3 user definable spot markers on camera and in

Smartview

®

Software

Hot and cold spot

markers

Center box (MIN-MAX-AVG)

Expandable-contractable measurement box

with MIN-MAX-AVG temp

Fixed-size measure-

ment box with

MIN-MAX-AVG temp

Drop

Engineered to withstand 2 meter (6.5 feet) drop

Size (H x W x L) / Weight (battery included)

28.4 cm x 8.6 cm x 13.5 cm / 0.726 kg

Enclosure rating

IP54 (protected against dust, limited ingress; protection against water spray from all directions)

Warranty

Two-years (standard), extended warranties are available

Recommended calibration cycle

Two-years (assumes normal operation and normal aging)

Supported Languages

Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish,

Swedish, Traditional Chinese, and Turkish