Background Image
Previous Page  52 / 164 Next Page
Information
Show Menu
Previous Page 52 / 164 Next Page
Page Background

48

500 Series Battery Analyzers

New

Fluke 500 Series Battery Analyzers cover a

broad range of battery test functions ranging

from DC voltage and resistance tests to full

condition testing using an automated string

function testing and the test probe integrated

infra-red temperature measurement system.

500 Series Battery Analyzers are designed for

measurements on stationary batteries of all

types.

• The world’s fastest battery measurements-

reduce time of a typical battery measurement

with 50% from 8 seconds to 4 seconds.

• Unique CATIII 600V safety rating

• Hands free wearable design

• Key measurements: Battery resistance, dc

and ac voltage, dc and ac current, ripple

voltage, frequency and battery temperature.

• Sequence measurement mode: Automatic or

manual sequence testing of battery strings

with automatic measurement storage

including voltage, resistance and temperature

(with BTL21 intelligent test probe).

• Optimized user interface: Quick, guided setup

ensures you’re capturing the right data every

time.

• Threshold comparison: Configure multiple

reference values and thresholds for

resistance and voltage. Comparison result

feedback after each measurement via visual

and verbal cues.

• Intelligent test probe set (BT520 and BT521):

Integrated LCD display, infrared temperature

measurement (BT521 only), verbal audio

feedback and captures voltage readings and

temperature logging automatically or via

integrated save button.

• Enhanced data analysis: Quickly compare

trends, analyze results and create reports

with included battery management software.

• Easy reporting: Generate PDF report on the

PC software with analysis graphics and data

table or quick email format report with csv

file on the mobile app.

More battery tests. Less time.

Results you can trust.

Included Accessories

4-wire test pin (set), BTL10 Basic Test Lead

(set), TL175 TwistGuard™Test Leads with

adapter, L300 Attachable LED Flashlight (2)

(BT520 and BT521 only), BTL20 Intelligent

Test Probe Set, with extender (no temperature

sensor)(BT520 only), BTL21 Intelligent Test

Probe Set, with extender and temperature

sensor (BT521 only), i410 AC/DC Current

Clamp (BT521 only), BP500 lithium-ion battery,

BC500 AC charger, Mini-USB cable, Shoulder

strap, Belt strap, Magnetic hanging strap,

FlukeView

®

Battery Management Software,

Soft carrying case, Spare fuses (2), Battery tags

(BT520 and BT521 only)

Ordering Information

Fluke BT510

Basic Battery Analyzer

Fluke BT520

Battery Analyzer

Fluke BT521

Advanced Battery Analyzer

Fluke BT520

Fluke BT521

Fluke BT521 included accessories

Fluke BT510

Specifications

Functions

Range Resolution Accuracy

BT510

BT520

BT521

Battery resistance

1

3 mΩ

0.001 mΩ

1 % + 8

30 mΩ

0.01 mΩ

0.8 % + 6

300 mΩ

0.1 mΩ

0.8 % + 6

3000 mΩ

1 mΩ

0.8 % + 6

Vdc

6 V

0.001 V

0.09 % + 5

60 V

0.01 V

0.09 % + 5

600 V

0.1 V

0.09 % + 5

1000 V

1 V

0.09 % + 5

Vac

(45 Hz to 500 Hz with 800 Hz filter)

600 V

0.1 V

2 % + 10

Frequency

(displayed withVac andAac)

2

500 Hz

0.1 Hz

0.5 % + 8

AC voltage ripple

(20 KHz Max)

600 mV

0.1 mV

3 % + 20

6000 mV

1 mV

3 % + 10

Adc/Aac

(with accessory Fluke i410)

400 A

1 A

3.5 % + 2

Temperature

0 °C to 60 °C

1 °C

2 °C (4 °F)

Meter mode

999 records for each measurement position with time stamp

Sequence mode

Up to 100 profiles and 100 profile templates

(Each profile stores up to 450 batteries) with time stamp

BT510

BT520

BT521

Size (hxwxd)

220 x 103 x 58 mm

Weight

850 g

Screen dimensions

77 x 56 mm

Interface

USB mini

Operating temperature

0 °C to 40 °C

Lithium-ion battery charging

temperature

0 °C to 40 °C

Operating humidity

Non-condensing (10 °C)

<=80 % RH (at 10 °C to 30 °C)

<=75 % RH (at 30 °C to 40 °C)

IP rating

IP40

Radio

FCC Class A

Vibration requirements

MIL-PRF-28800F: Class 2

Drop test requirements

1 meter

Temperature coefficients

Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

Safety compliance

600 V CAT III

1

The measurement is based on ac injection method.The injected source signal is <100 mA,1 kHz.

2

Trigger levelVAC: 10 mV,Aac: 10A

Intelligent test probe with

integrated LCD display