69
50 Series II Thermometers
FVF-SC 2
See page 155
TPAK
See page 155
Recommended Accessories
Fluke 54 II B
Fluke 51 II
Features
80PK-25
See page 150
Battery life:
1000 hours typical, AA
Size (HxWxD):
173 x 86 x 38 mm
Weight:
0.4 kg
Three Year Warranty
Included Accessories
Impact absorbing holster
Two bead probe thermocouples 80PK-1 (54+52)
One bead probe thermocouple 80PK-1 (51+53)
Ordering Information
Fluke 51 II Thermometer
Fluke 52 II Thermometer
Fluke 53 II B Thermometer
Fluke 54 II B Thermometer
FVF-SC2
FlukeView Forms Software
including USB interface cable
The Fluke 50 Series II contact
thermometers offer fast response and
laboratory accuracy (0.05% + 0.3°C) in
a rugged handheld test tool.
• Large backlit dual display shows any
combination of T
1
, T
2
(52 and 54 only),
T
1
-T
2
(52 and 54 only) plus MIN, MAX,
or AVG
• Relative time clock on MIN, MAX, and
AVG provides a time reference for major
events
• Electronic Offset function allows
compensation of thermocouple errors
to maximize overall accuracy
• Readout in °C, °F, or Kelvin (K)
• Sleep mode increases battery life
• Battery door allows easy battery
replacement without breaking the
calibration seal
Additional features for the 53 and
54 Series II:
• Data Logging up to 500 points of data
with user adjustable recording interval
• Real time clock captures the exact time
of day when events occur
• Recall function allows logged data to be
easily reviewed on the meter display
• IR communication port allows data to
be exported to optional FlukeView
®
PC software
51 II
52 II
53 II B
54 II B
Thermocouple types
J,K,T,E
J,K,T,E
J,K,T,E,N,R,S J,K,T,E,N,R,S
Number of inputs
Single
Dual
Single
Dual
Time stamp
Relative Time Relative Time Time of Day Time of Day
Splash/Dust resistant
●
●
●
●
Dual display with backlight
●
●
●
●
Min/Max/Avg recording
●
●
●
●
(T
1
-T
2
) True differential
●
●
Data logging up to 500 points
●
●
IR data port for interface
to PC
●
●
Compatible with optional
FlukeView Software
●
●
80PK-26
See page 150
Fluke 52 II
Fluke 53 II B
Specifications
C25
See page 152
**Only the Fluke Models 53 and 54 Series II thermometers are capable of measuring N, R, and S-type
Temperature range:
J-type Thermocouples
-210°C to 1200°C
K-type Thermocouples
-200°C to 1372°C
T-type Thermocouples
-250°C to 400°C
E-type Thermocouples
-150°C to 1000°C
N-type** Thermocouples
-200°C to 1300°C
R** and S-type** Thermocouples
0°C to 1767°C
Temperature accuracy
Above –100°C (-148°F):
J, K,T, E, and N-type**
± [ 0.05% + 0.3°C ]
R** and S-type**
± [ 0.05% + 0.4°C ]
Below –100°C (-148°F):
J, K, E, and N-types
± [ 0.20% + 0.3°C ]
T-type
± [ 0.50% + 0.3°C ]
Laboratory accuracy. Wherever you go.