Background Image
Previous Page  69 / 164 Next Page
Information
Show Menu
Previous Page 69 / 164 Next Page
Page Background

65

572-2 High Temperature

Infrared Thermometer

• Measure -30 °C to 900 °C

• 60:1 distance to spot ratio with dual laser sighting for fast, accurate targeting

• Multi-language interface (user select)

• Current Temperature plus MAX, MIN, DIF, AVG temperature displays

• Compatible with standard mini-connector K-type thermocouples,

including ones you already own and have installed

• Adjustable emissivity and predefined emissivity table

• Infrared and thermocouple temperature on backlit display

• Last reading Hold (20 seconds)

• High and low temperature alarm

• Data storage and review (99 data sets)

• Tripod mount

• 12 or 24 hour clock

• USB 2.0 computer interface cable

• FlukeView

®

Forms Documenting Software

Included Accessories

K-type thermocouple bead probe, USB 2.0

computer interface cable, FlukeView

®

Forms

Documenting Software, hard carrying case,

getting started guide (print) and user’s manual

(CD).

Ordering Information

Fluke 572-2 Infrared Thermometer

Features

The Fluke 572-2 Infrared Thermometer

is the one product you can use in high-

temperature industrial environments

all around the world. Whether you work

in power utility, metal refining and

smelting, glass, cement or petrochemical

environments, the new 572-2 allows you

to carry the most trusted name in test

tools anywhere you need accurate, high

temperature and high distance-to-spot

measurements.

With a rugged, easy-to-use, ergonomic

design, the Fluke 575-2 can stand up

to tough industrial, electrical, and

mechanical environments.

The best choice when things are really hot

Infrared temperature range

-30 °C to 900 °C

IR accuracy (Calibration geometry with

ambient temperature 23 °C ± 2 °C)

≥ 0 °C: ± 1°C or ± 1 % of the reading, whichever is greater

≥-10 °C to <0 °C: ± 2 °C

<-10 °C: ± 3 °C

IR Repeatability

± 0.5 % of reading or ± 0.5 °C, whichever is greater

Display Resolution

0.1 °C

Distance:Spot

60:1 (calculated at 90 % energy)

Minimum spot size

19 mm

Laser sighting

Offset dual laser, output <1 mW

Spectral Response

8 μm to 14 μm

Response Time (95 %)

<500 ms

Emissivity

Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in

table of common materials

Hi/Low alarms

Audible and two-color visual

Min/Max/Avg/Dif

Yes

Switchable celsius and fahrenheit

Yes

Backlight

Two levels, normal and extra bright for darker environments

Trigger lock

Yes

Data storage

99 points

Display

Dot matrix 98 x 96 pixels with function menus

Communication

USB 2.0

K-type thermocouple input temperature range

-270 °C to 1372 °C

K-type thermocouple input accuracy (with

ambient temperature 23 °C ± 2 °C)

< -40 °C: ± (1 °C + 0.2 °/1 °C) ≥ -40 °C: ± 1 % or 1 °C, whichever

is greater

Specifications

Operating temperature:

0 °C to 50 °C

Storage temperature:

-20 °C to 60 °C

Size (HxWxD):

177 x 164 x 52 mm

Weight:

0.322 kg

Power:

2 AA Batteries

Battery life:

8 hours with laser and backlight on;

100 hours with laser and backlight off, at 100 % duty

cycle (thermometer continuously on)

Two years warranty

Recommended Accessories

80PK-26

See page 150

80PK-25

See page 150

80PK-11

See page 150

80PK-9

See page 150

80PK-8

See page 150

80-PK-1

See page 150

Fluke 572-2