5608/5609/5609-BND

5627A

5615

21

Temperature Calibration

Precision PRTs

High accuracy reference

temperature measurements in

temperature sources on the

bench or in the field.

5627A Precision

Industrial PRT

Vibration and shock resistant

Calibration accuracy of

± 0.046 °C at 0 °C

Available with a 90° bend

NVLAP-accredited calibration

included, lab code 200706-0

www.flukecal.eu/5627

5615 Secondary Reference

Temperature Standards

–200 °C to 420 °C

Calibrated accuracy ± 0.010 °C

at 0 °C

NVLAP-accredited calibration

included, lab code 200706-0

www.flukecal.eu/5615

5608/5609/5609-BND

Secondary Reference PRTs

Drift rate of ± 0.01 °C at 0 °C after

100 hours at max temperature.

5608: –200 °C to 500 °C

(80 mm minimum immersion)

5609: –200 °C to 670 °C

(100 mm minimum immersion)

Comes with certificate

of compliance - optional

NVLAP-accredited calibration

www.flukecal.eu/5608

5622 Fast Response PRTs

Time constants as fast as

0.4 seconds

Small probe diameters ranging

from 0.5 mm to 3.2 mm (four

models available)

Available as DIN/IEC Class

A PRTs or with optional

NVLAP-accredited calibration,

lab code 200348-0

www.flukecal.eu/5622

5626/5628 Secondary SPRT,

PRT, Temperature Sensors

Range to 661°C

Meets all ITS-90 requirements

for resistance ratios

Rtp drift < 20 mK after 500

hours at 661°C

Calibrated accuracy of ± 0.006

°C at 0 °C

NVLAP accredited fixed point

calibration

www.flukecal.eu/5622

5618B Small Diameter

Industrial RTD

Fast response for time-dependent

measurements.

Small diameter sheath, 3.2 mm

(0.125 in)

Excellent stability

Includes ITS-90 coefficients

NVLAP accredited calibration,

lab code 200706-0

www.flukecal.eu/5618B

5606 Full Immersion PRT

Fully immerse PRT transition

junction inside freezers or

furnaces.

Transition junction designed

to withstand full temperature

range of probe

-200 °C to 160 °C

Calibration accuracy of

± 0.05 °C (full range)

Optional NVLAP accredited

calibration

www.flukecal.eu/5606

Thermistors

Providing accurate and rugged

temperature measurements from

0 °C to 100 °C.

5610/5611/5611T

Secondary Reference

Thermistor Probes

Economical lab-grade therm-

istor probes with low drift

susceptibility.

Short-term accuracy to

± 0.01 °C; one-year drift

< ± 0.01 °C

5610: 3.2 mm diameter stain-

less steel sheathed thermistor

5611: 1.5 mm diameter (tip)

silicone coated thermistor

5611T: 3 mm diameter (tip)

PTFE encapsulated thermistor

www.flukecal.eu/5610

5610

5622

5611T

5606

5611

5626/5628