Background Image
Previous Page  26 / 164 Next Page
Information
Show Menu
Previous Page 26 / 164 Next Page
Page Background

22

v3000 FC Wireless AC Voltage Module /

v3001 FC Wireless DC Voltage Module

See it. Save it. Share it.

All the facts, right in the field. The Fluke v3000 FC Wireless AC Voltage Module and

Fluke v3001 FC Wireless DC Voltage Module are members of a family of wireless test

tools that let you share test data using the Fluke Connect™ app with ShareLive™

video call.

Fluke v3001 FC Wireless DC Voltage

Module

A fully functional DC voltage meter

that wirelessly relays DC voltage

measurements to other Fluke Connect™

enabled master units.

v3001 FC main features include:

• Measure up to 1000 V DC

• Use as a standalone meter or as part of

the system

• Logging function for recording and

saving up to 65,000 readings

Fluke v3000 FC Wireless True-RMS AC

Voltage Module

A fully functional True RMS voltage

meter that wirelessly relays AC voltage

measurements to other Fluke Connect™

enabled master units.

v3000 FC main features include:

• True-RMS AC voltage module

• Measure up to 1000 V

• Use as a standalone meter or as part of

the system

• Logging function for recording and

saving up to 65,000 readings

Recommended Accessories

Included Accessories

TL224 Test leads, AC285 Alligator Clips,

Magnetic hanging strap

Ordering Information

Fluke v3000FC FC Wireless AC Voltage

Module

Fluke v3001FC FC Wireless DC Voltage

Module

True RMS

Fluke v3000 FC

Fluke v3001 FC

Range

1

Resolution

Accuracy

2,3,4

45 Hz to

500 Hz

500 Hz to

1 kHz

6.000 V 0.001 V

1.0 % + 3 2.0 % + 3

60.000 V 0.01 V

600.0 V

0.1 V

1000 V

1 V

AC voltage

Function Range

Resolution Accuracy

mV dc

600.0 mV 0.1 mV 0.09 % +3

V dc

6.000 V 0.001 V

0.09 % +3

60.00 V 0.01 V

600.0 V 0.1 V

1000 V 1 V

0.15 % + 2

DC voltage

1 All ac voltage ranges are specified from 1 % of range to 100 % of range.

2 Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor ≤ 1.5 at 1000V.

3 For non-sinusoidial waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.

4

Do not exceed 106V-Hz.

Model / specification

v3000 / v3001

LCD w/backlight

3½ digits, 6000 counts, updates 4/sec

Battery type

2 AA, NEDA 15 A, IEC LR6

Log rate/Interval

Adjustable by PC from 1 sec to 1 hr, default 1 min

Battery life

400 hours

Memory

Record up to 65000 readings

RF communications

2.4 GHZ ISM Band

RF communication range

Open air, unobstructed: Up to 20 m

Obstructed, sheetrock wall: Up to 6.5 m

Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m

Operating temperature

-10 °C to +50 °C

Storage temperature

-40 °C to +60 °C

Temperature coefficient

0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)

Operating humidity

90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C

Altitude

Operating: 2,000 m

Storage: 12,000 m

EMC

EN 61326-1:2006

Safety compliance

ANSI/ISA 61010-1 / (82.02.01): 3rd edition

CAN/CSA-C22.2 No 61010-1-12: 3rd edition

UL 61010-1: 3rd edition

IEC/EN 61010-1:2010

Safety rating

CAT IV 600 V, CAT III 1000 V

Certifications

CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE

Ingress Protection (IP) rating

IP42

Pollution Degree

2

Size (hxwxd)

16.5 cm x 6.35 cm x 1.4 cm

Weight

0.22 kg

Specifications

AC87

See page 147

AC220

See page 147

PC adapter

See page 155

For more information on Fluke Connect,

see pages 13-18

Fluke V3000FC Wireless AC Voltage Module with test leads

and alligator clips