22
v3000 FC Wireless AC Voltage Module /
v3001 FC Wireless DC Voltage Module
See it. Save it. Share it.
All the facts, right in the field. The Fluke v3000 FC Wireless AC Voltage Module and
Fluke v3001 FC Wireless DC Voltage Module are members of a family of wireless test
tools that let you share test data using the Fluke Connect™ app with ShareLive™
video call.
Fluke v3001 FC Wireless DC Voltage
Module
A fully functional DC voltage meter
that wirelessly relays DC voltage
measurements to other Fluke Connect™
enabled master units.
v3001 FC main features include:
• Measure up to 1000 V DC
• Use as a standalone meter or as part of
the system
• Logging function for recording and
saving up to 65,000 readings
Fluke v3000 FC Wireless True-RMS AC
Voltage Module
A fully functional True RMS voltage
meter that wirelessly relays AC voltage
measurements to other Fluke Connect™
enabled master units.
v3000 FC main features include:
• True-RMS AC voltage module
• Measure up to 1000 V
• Use as a standalone meter or as part of
the system
• Logging function for recording and
saving up to 65,000 readings
Recommended Accessories
Included Accessories
TL224 Test leads, AC285 Alligator Clips,
Magnetic hanging strap
Ordering Information
Fluke v3000FC FC Wireless AC Voltage
Module
Fluke v3001FC FC Wireless DC Voltage
Module
True RMS
Fluke v3000 FC
Fluke v3001 FC
Range
1
Resolution
Accuracy
2,3,4
45 Hz to
500 Hz
500 Hz to
1 kHz
6.000 V 0.001 V
1.0 % + 3 2.0 % + 3
60.000 V 0.01 V
600.0 V
0.1 V
1000 V
1 V
AC voltage
Function Range
Resolution Accuracy
mV dc
600.0 mV 0.1 mV 0.09 % +3
V dc
6.000 V 0.001 V
0.09 % +3
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
0.15 % + 2
DC voltage
1 All ac voltage ranges are specified from 1 % of range to 100 % of range.
2 Crest factor of ≤ 3 at full scale up to 500V, decreasing linearly to crest factor ≤ 1.5 at 1000V.
3 For non-sinusoidial waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
4
Do not exceed 106V-Hz.
Model / specification
v3000 / v3001
LCD w/backlight
3½ digits, 6000 counts, updates 4/sec
Battery type
2 AA, NEDA 15 A, IEC LR6
Log rate/Interval
Adjustable by PC from 1 sec to 1 hr, default 1 min
Battery life
400 hours
Memory
Record up to 65000 readings
RF communications
2.4 GHZ ISM Band
RF communication range
Open air, unobstructed: Up to 20 m
Obstructed, sheetrock wall: Up to 6.5 m
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m
Operating temperature
-10 °C to +50 °C
Storage temperature
-40 °C to +60 °C
Temperature coefficient
0.1 X (specified accuracy)/°C (< 18 °C or > 28 °C)
Operating humidity
90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
Altitude
Operating: 2,000 m
Storage: 12,000 m
EMC
EN 61326-1:2006
Safety compliance
ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 No 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010
Safety rating
CAT IV 600 V, CAT III 1000 V
Certifications
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
Ingress Protection (IP) rating
IP42
Pollution Degree
2
Size (hxwxd)
16.5 cm x 6.35 cm x 1.4 cm
Weight
0.22 kg
Specifications
AC87
See page 147
AC220
See page 147
PC adapter
See page 155
For more information on Fluke Connect,
see pages 13-18
Fluke V3000FC Wireless AC Voltage Module with test leads