28
27 II
28 II / 28 II Ex
IP 67 waterproof & dustproof protection
●
●
Withstands 3 meter drop (with holster)
●
●
True-RMS measurements
●
Digital display counts
6000
20000/6000
Bright, two-level backlight
●
●
Backlit keypad buttons
●
●
Reversible, rubber holster
●
●
Built-in thermometer
●
Resistance, continuity and diode test
●
●
Min/Max and average recording
●
●
Improved sleep mode for long battery life
●
●
Relative mode to remove test lead resistance
from low ohms measurements
●
●
Auto and manual ranging
●
●
Safety rating
CAT III 1000 V
CAT IV 600 V
CAT III 1000 V
CAT IV 600 V
ATEX
safety rating II 2 G Ex ia IIC T4 Gb II 2 D
Ex ia IIIC T130 °C Db I M1 Ex ia I Ma
28 II Ex
27II / 28II Rugged IP67 Industrial
Multimeters
Included Accessories
TL175 Test leads, AC175 alligator clips,
80BK-A temperature probe (28 II), holster,
manual, CD-ROM, three AA batteries
(installed)
Ordering Information
Fluke 27 II
IP 67 Industrial Multimeter
Fluke 28 II
IP 67True-RMS Industrial
Multimeter
Fluke 28 II Ex Intrinsically safeTrue-RMS
Industrial Multimeter
The Fluke 27 II and 28 II digital
multimeters define a new standard for
operating in harsh conditions with the
features and accuracy to troubleshoot
most electrical problems. Both meters
have IP 67 (waterproof and dustproof)
rating, MSHA approvals, extended
operating temperature range of -15° C to
+ 55°C and 95% humidity, and a 3-meter
drop. They withstand hazardous 8.000
volt spikes caused by load switching and
faults on industrial circuits and complies
with second edition IEC and ANSI
electrical safety standards.
Furthermore, the 28 II has a unique
function for accurate voltage and
frequency measurements on adjustable
speed motor drives and other electrically
noisy equipment.
The new Fluke 20 series multimeters
are built to work in the toughest
environments.
For 28II Ex see also page 135 and 136.
Recommended Accessories
Battery Life:
3x AA alkaline, 800 hrs typical
Size (HxWxD):
198 x 100 x 63.5 mm
Features
Specifications
Functions
Maximum Max.
Resolution
27 II
28 II / 28 II Ex
Voltage DC
1000 V
0.1 mV ±(0.1% + 1)
±(0.05% + 1)
Voltage AC
1000 V
0.1 mV ±(0.5% + 3)
±(0.7% + 4)
Current DC
10 A
0.1 μA
±(0.2% + 4)
±(0.2% + 4)
Current AC
10A
0.1 μA
±(1.5% + 2)
±(1.0% + 2)
Temperature
-200°C to
+1090°C
0.1°C
±(1% + 10)
Resistance
50MΩ
0.1Ω
±(0.2% + 1)
Low pass filter (Measurement on VSD’s)
yes
Capacitance
9999μF
0.01nF
±(1% + 2)
Frequency
200 kHz
0.01 Hz
0.005% + 1
Peak transient capture
250 μS
Weight:
0.75 kg
Lifetime Warranty
Designed to survive water, dust and rough
handling and yet troubleshoot most electrical
problems
Accuracies are best accuracies for each function
On all inputs
True RMS
PV 350
See page 154
i200
See page 148
i410
See page 149
80K-6
See page 156
Fluke 28II Ex
Fluke 27 II
Fluke 28 II