110 Series Digital Multimeters
The Fluke 110 Series has five true-rms
DMMs, each for specific users. The compact
instruments offer convenient one-handed
operation and a backlit display with large, easy-
to-read digits.
Fluke 117 Electrician’s Multimeter with
Non-Contact Voltage
The 117 is for electricians working in
commercial and non-commercial premises
(like hospitals and schools). It includes extras
like non-contact voltage detection for faster
and safer operation.
Fluke 116 Multimeter with Temperature
and Microamps
The 116 is for heating, ventilation and air
conditioning (HVAC) engineers. It includes
temperature measurement and microamp
current ranges to quickly troubleshoot HVAC
problems.
Fluke 115 Field Service Testing
Multimeter
An everyday multimeter for technicians, the
115 is for electrical and electronic testing in
field service, industrial, and applications where
more than the basic functions simplify work.
Fluke 114 Electrical Multimeter
The 114 is for electrical troubleshooting and
straightforward ‘go/no-go’ in residential/
commercial testing. It has all the basic
functions plus a special feature to prevent false
readings caused by ghost voltage.
Fluke 113 Multimeter
The 113 is for basic electrical tests and
repairing most electrical problems. Features
include Fluke’s VCHEK™, added measurement
functions, backlight and conformance to the
latest safety standards.
Recommended Accessories
C50
See page 152
(Check the Fluke web for detailed specifications)
TL223-1
See page 145
MC6
See page 156
TPAK
See page 155
Features
Accuracies are best accuracies for each function
Battery type:
9 volt Alkaline, 400 hours typical
Size (HxWxD):
167 mm x 84mm x 46 mm
Specifications
Weight:
0.55 kg (including batteries)
Three Year Warranty
Compact design for ergonomic
one-handed operation
113
114
115
116
117
True RMS readings
AC
AC
AC
AC
AC
Counts
6000
6000
6000
6000
6000
Backlight
●
●
●
●
●
Analog bargraph
●
●
●
●
●
AutoVolt: Automatic AC/DC voltage selection
●
●
●
VoltAlert™, Non-contact voltage detection
●
Built-in thermometer for HVAC applications
●
LoZ: low input impedance to prevent ghost voltage
●
●
●
VCHEK™ LoZ low impedance measurement function to
simultaneously test for voltage or continuity
●
Min/Max/Average to record signal fluctuations
●
●
●
●
●
Resistance, continuity
●
●
●
●
●
Frequency, Capacitance, Diode test
-/
●
/
●
●
●
●
Microamps to test flame sensors
●
Display hold
●
●
●
●
●
Auto/manual ranging
●
●
●
●
●
Low battery indication
●
●
●
●
●
Compact case with removable holster
●
●
●
●
●
Functions
Maximum Max. resolution
113
114
115
116
117
Voltage DC
600V
1mV
±(0.5%+2)
±(0.5%+2)
±(0.5%+2)
±(0.5%+2)
±(0.5%+2)
Voltage AC
600V
1mV
±(1.0%+3)
±(1.0%+3)
±(1.0%+3)
±(1.0%+3)
Current DC
10.00A
1mA
±(1.0%+3)
±(1.0%+3)
Current AC
10.00A
0.01A
±(1.5%+3)
±(1.5%+3)
Resistance
40MΩ (113: 60KΩ) 0.1Ω
±(0.9%+2)
±(0.9%+1)
±(0.9%+1)
±(0.9%+1)
±(0.9%+1)
Capacitance
10000μF
1nF
±(1.9%+2)
±(1.9%+2)
±(1.9%+2)
±(1.9%+2)
Frequency
50kHz
0.01Hz
±(0.1%+2)
±(0.1%+2)
±(0.1%+2)
Temperature
-40°C/+400°C 0.1°C
±(1.0%+10)
VCHEK™
600.0V AC/DC 0.1V
±(2.0%+3)
Fluke 117
Fluke 115
Fluke 116
Fluke 114
True RMS
On all inputs
Fluke 113
Included Accessories
Test leads with 4 mm lantern tips, holster,
installed 9V battery and users manual
Ordering Information
Fluke 113
True RMS Multimeter
Fluke 114
True RMS Multimeter
Fluke 115
True RMS Multimeter
Fluke 116
True RMS Multimeter
Fluke 117
True RMS Multimeter
Fluke 117/323 Kit
Electricians Combo Kit
Fluke 116/62 MAX+ Kit Combo Kit
Fluke 116/323 Kit
Combo Kit
(see page 5)