34

Clamps Selection Guide

Residential/commercial

electrical

General purpose

Industrial

electrical HVAC/R High end industrial,

utility

iFlex

accessory

Fluke Connect

Leakage

323

324

325

365

373

374

375 376/381 902

353

355 i2500-10/

i2500-18 a3000FC a3001FC

1

a3002FC

1

360

Measurements

AC current

AC volts

Resistance

Continuity

DCVolts

DC current

True-rms

Frequency

AC + DC voltage

AC + DC current

Min/Max/Avg

Temperature

Capacitance

Special features

Inrush current mode

Low Pass filter

Harmonics, power, data logging

- / - /

- / - /

- / - /

18” iFlex Flexible Current Probe

Optional

Optional

Included

10” iFlex Flexible Current Probe

Optional

Optional

Optional

Remote display

- /

Flashlight/torch

Display

Display hold

Backlight

Specifications

Jaw opening

30 mm

30 mm

30 mm

18 mm 32 mm 34 mm 34 mm 34 mm 30.5 mm 58 mm 58 mm 7.5 mm coil

34 mm 254 mm

40 mm

Current range ac rms

0 to 400.0 A 0 to 400.0 A 0 to 400.0 A 0 to 200.0 A 0 to 600.0 A 0 to 600.0 A 0 to 600.0 A 0 to 999.9 A 0 to 600.0 A 0 to 1400 A 0 to 1400 A 0 to 2500 A 0.5 to 400 A 0.5 to 2500 A 0.5 to 600 A 0 to 60 A

Accuracy ac current (50/60 Hz)

2,00%

± 5 counts

1,50%

± 5 counts

2,00%

± 5 counts

2 %

± 5 counts

2 %

± 5 counts

2 %

± 5 counts

2 %

± 5 counts

2 %

± 5 counts

2 %

± 5 counts

1.5 %

± 5 counts

1.5 %

± 5 counts

3 %

± 5 counts

2%

± 5 counts

3%

± 5 counts

AC: 1.0%±3 counts

DC: 0.5%±3 counts

1 %

± 5 counts

AC Response

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

True-rms

Averaging

Current range dc

0 to 400A 0 to 200 A

0 to 600.0 A 0 to 600.0 A 0 to 999.9 A 0 to 200 μA 0 to 2000 A 0 to 2000 A

0 to 1000 A

Accuracy dc current

2 %

± 5 counts

2 %

± 5 counts

2 %

± 5 counts

2 %

± 5 counts

2 %

± 5 counts

1 %

± 5 counts

1,5 %

± 5 counts

1,5 %

± 5 counts

0,5 %

± 3 counts

Voltage range ac

0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 1000 V 600.0V

0 to 600.0 V

Accuracy ac voltage

1,5%

± 5 counts

1,5%

± 5 counts

1,5%

± 5 counts

2 %

± 5 counts

1 %

± 5 counts

1,5 %

± 5 counts

1,5 %

± 5 counts

1,5 %

± 5 counts

1 %

± 5 counts

1 %

± 5 counts

Voltage range dc

0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 600.0 V 0 to 1000 V 0 to 600.0 V

0 to 1000 V

Accuracy dc voltage

1 %

± 5 counts

1 %

± 5 counts

1 %

± 5 counts

2 %

± 5 counts

1 %

± 5 counts

1 %

± 5 counts

1 %

± 5 counts

1 %

± 5 counts

1 %

± 5 counts

1 %

± 5 counts

Resistance range

0 to 4000 Ω

0 to 4000 Ω 0 to 4000 Ω

0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 60 kΩ 0 to 9999 Ω

0 to 400 kΩ

Frequency measurement range

500 Hz

500 Hz

500 Hz

5 to 1000 Hz 5 to 1000 Hz

500 Hz

Unit power

Auto off

Warranty and safety

Warranty (years)

2

2

2

3

3

3

3

3

3

3

3

3

3

3

3

1

Category ratings (EN61010-1)

CAT III 600 V,

CAT IV 300 V

CAT III 600 V,

CAT IV 300 V

CAT III 600 V,

CAT IV 300 V CAT III 600 V CAT III 600 V,

CAT IV 300 V

CAT III 1000 V,

CAT IV 600 V

CAT III 1000 V,

CAT IV 600 V

CAT III 1000 V,

CAT IV 600 V CAT III 600 V CAT III 1000 V,

CAT IV 600 V

CAT III 1000 V,

CAT IV 600 V

CAT III 1000 V,

CAT IV 600 V CAT III 600 V CAT III 1000 V,

CAT IV 600 V

CAT III 1000 V,

CAT IV 600 V CAT III 300 V

1 Clamp not included