40
360 Leakage Clamp Meter
Included accessories
Test leads, temperature probe (Fluke 902),
soft carrying pouch and users manual
Ordering information
Fluke 360
Leakage Clamp Meter
Fluke 902 True-rms HVAC Clamp Meter
Features
• Measurement of leakage protectives
conductor and touch current with a
resolution of 1μA
• Advanced shielding to ensure accurate
results when measuring near other
conductors
• Automatic ranging within the manually
selected mA or A range
• Easily viewed measurements on digital
and bargraph display and HOLD when
measuring in hard to see locations
• Broad range of measurements currents
up to 60 A for all installation needs
• Easy carrying, pocket sized clamp with
wide 40 mm jaw size
• Display-Hold for convenience in use
• Auto power off with audible warning
buzzer
• Conformance to IEC61010 and EMC
standard
• Meets all the applications and
performance classes in safety standard
VDE0404-4 and the new VDE0702
leakage
current 0.5mA
ground
Specifications
Fluke 360
Functions
Range
Resolution
Accuracy
Current AC
3mA
30mA
0.001A
0.01mA
1% ± 5 counts
30A
60A
0.01A
0.1A
1% ± 5 counts (0~50A)
5% ± 5 counts (50~60A)
Frequency
50 and 60Hz
(Check the Fluke web for detailed specifications)
leakage current
1.2mA (e.g. via
motor shaft)
display: 1.7mA
Leakage current measurements with a tough,
pocket sized clamp meter
902 True-rms HVAC Clamp Meter
HVAC (heating, ventilation, air
conditioning) technicians require a service
tool that can consistently keep up with
their demands. The Fluke 902 expands the
existing line of quality Fluke clamp meters
by delivering the features necessary
to diagnose and repair HVAC systems.
Combined with true-rms technology
and a CAT III 600 V rating, the Fluke 902
helps technicians do their jobs safely and
accurately.
• Designed for HVAC applications with
capacitance, dc current (μA), and
temperature measurements
• Small body and jaws fit perfectly in your
hand and into tight places
• Handy “Display Hold” button keeps
measurements on the display
• Meter controls are positioned so current
measurements can be done with one
hand (index finger on clamp opening
lever and thumb on rotary switch)
• Three-year warranty
See specifications chart on page 34
Just for our HVAC pros
True RMS
Functions
Range
902
Current AC
0 to 600.0 A
2% ± 5 counts
Current DC
0 to 200.0 μA
1% ± 5 counts
Voltage AC
0 to 600.0 V
1% ± 5 counts
Voltage DC
0 to 600.0 V
1% ± 5 counts
Resistance range
0 to 9999 Ω
Jaw opening
30.5 mm
Max. wire size
750 MCM
Fluke 902
Specifications