Background Image
Previous Page  39 / 164 Next Page
Information
Show Menu
Previous Page 39 / 164 Next Page
Page Background

35

a3000FC / a3001FC / a3002FC

FC Wireless Current Clamp and Modules

Specifications

Model / specification

a3000

a3001

a3002

Range

0.5 A to 400.0 A AC

0.5 A to 2500 A AC

600 A AC to 1000 A AC

Resolution

0.1 A

Accuracy

400.0 A: 2 % ± 5 digits

(10 Hz to 100 Hz),

2.5 % ± 5 digits

(100 Hz to 500 Hz)

3 % ± 5 digits

(5 Hz to 500 Hz)

AC: 1.0% + 3

DC: 0.5% + 3

(45 Hz to 1000 Hz)

Inrush

Max displayed reading: 999.9A

Crest Factor (50Hz/60Hz)

3 at 500 A, 2.5 at 600 A, 1.42 at

1000 A, add 2 % for C.F. > 2

3.0 at 1100 A, 2.5 at 1400 A, 1.42

at 2500 A, add 2 % for C.F. > 2

Maximum voltage between terminal

and earth ground (module)

n.a.

n.a.

30V DC or AC rms

LCD w/backlight

3½ digits

3 ½ digits, 6000 counts,

4/sec update rate

Log rate/interval

1 sec minimum/adjustable by PC or FC App

Battery type/Battery life

2 AA, NEDA 15 A, IEC LR6 / 400 hours

Memory

Record up to 65,000 readings

RF communications /

RF communication range

2.4 GHZ ISM Band / Open air, unobstructed: Up to 20 m. Obstructed, sheetrock wall: Up to 6.5 m.

Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m

Operating and Storage temperature

-10 °C to +50 °C / -40 °C to +60 °C

Temperature coefficient

Add 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)

Operating humidity

0 % to 90 % (0 °C to 35 °C), 0 % to 75 % (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)

Altitude

Operating: 2,000 m Storage: 12,000 m

EMC

EN 61326-1:2006

Safety compliance

IEC 61010-1, 600V CAT III, 3rd

edition Pollution Degree 2

IEC 61010-1, 600V CAT IV/1000V CAT III,

3rd edition Pollution Degree 2

Safety rating

CAT III 600V

CAT IV 600V, CAT III 1000V

Certifications

CSA, CE,

FCC:T68-FBLE

IC: 6627A-FBLE

Ingress Protection (IP) rating

IP30

IP42

Pollution Degree

2

Jaw Opening

34 mm

25.4 cm coil

Size (hxwxd)

20.3 cm x 7.49 cm x 3.55 cm 16.5 cm x 6.35 cm x 1.4 cm 16.0 cm x 6.6 cm x 3.8 cm

Weight

0.22 kg

0.22 kg

0.255 kg

Warranty (in years)

3

True RMS

Included Accessories

iFlex i2500 Flexible Current Probe (a3001FC),

magnetic hanging strap (a3002FC)

Ordering Information

Fluke a3000FC

Wireless AC Current Clamp

Module

Fluke a3001FC

Wireless iFlex AC Current

Module

Fluke a3002FC

Wireless AC/DC Current

Module

Fluke a3000 FC

Fluke a3001 FC

Fluke a3002 FC

Recommended Accessories

PC adapter

See page 155

i410/i1010

Current Clamp

(for a3002FC)

See page 151

For more information on Fluke Connect,

see pages 13-18.

Fluke a3000FC

Wireless AC Current Clamp Module

Fluke a3001FC

Wireless iFlex AC Current Module

Fluke a3002FC

Wireless AC/DC Current Module

A fully functional True rms current clamp

meter that wirelessly relays measurements

to other Fluke Connect™ enabled master

units.

A true-rms current clamp meter that

wirelessly relays measurements to other

Fluke Connect™ enabled masterunits. The

iFlex™Wireless Current Module allows

you to measure around awkward sized

conductors or get into tight spaces and

makes wire access easier.

Designed to be used with the i410 or i1010

AC/DC current clamps (not included with

module). AC/DC current module that

wirelesly relays measurements from the

i410 or i1010 clamp accessory to other Fluke

Connect™ enabled master units.

a3000FC main features include:

• Measure up to 400 A AC

• Logging function for recording and saving up

to 65,000 readings

• Use as a standalone meter or as part of a system

• Inrush function

a3001FC main features include:

• Measure up to 2500 A AC

• Logging function for recording and saving up

to 65,000 readings

• Use as a standalone meter or as part of a system

• Inrush function

a3002FC main features include:

• Measure up to 400 A AC or 400 A DC with i410

(sold separately)

• Measure up to 600 A AC or 1000 A DC with i1010

(sold separately)

• Use as a standalone meter or as part of a system

• Logging function for recording and saving up to

65,000 readings