Background Image
Previous Page  42 / 164 Next Page
Information
Show Menu
Previous Page 42 / 164 Next Page
Page Background

38

370 Series Clamp Meters

Included Accessories

18-inch iFlex

flexible current Probe (Fluke

376), test leads, soft carrying case, instruction

card, safety information sheet,

two AA alkaline batteries.

Ordering Information

Fluke 376 True-rms AC/DC Clamp Meter

with iFlex

Fluke 375 True-rms AC/DC Clamp Meter

Fluke 374 True-rms AC/DC Clamp Meter

Fluke 373 True-rms AC Clamp Meter

i2500-10 iFlex™ Flexible Current Probe 25 cm

i2500-18 iFlex™ Flexible Current Probe 45 cm

Our new family of true-rms clamp meters

provides a range of state of-the-art features

to meet even the most demanding job

requirements.

All four of the new clamp meters have

improved base features such as a large,

backlit display, true-rms standard, CAT IV

safety rating and a durably constructed

body. Additionally, the 376, 375 and 374

are compatible with the iFlex flexible

current probe (included with the 376,

sold separately for the 375 and 374), and

provide increased measurement readings

to 1000 A and 1000 V AC and DC.

Recommended Accessories

True RMS

Fluke 374 Fluke 373

Fluke 375

Fluke 376

(with i2500)

Fluke i2500

Be ready for anything

iFlex

Flexible Current Probe

Specifications

TL175

See page 147

TL223-1

See page 145

AC285

See page 147

The Fluke iFlex flexible current probes expand the measurement range of select Fluke

meters to 2500 A AC and allow technicians to reach crowded spaces.

• Expands the measurement range to 2500 A AC while providing increased display

flexibility, ability to measure awkward sized conductors and improved wire access

• Compatible to Fluke 374, 375, 376 and 381

• CAT IV 600 V, CAT III 1000 V

• 7.5 mm coil diameter allows measurement in tight spaces

• Ergonomic design allows easy operation with one hand

• 1.8 m cable

• Three-year warranty

373

374

375

376

True-rms

AC current

AC voltage

Resistance

Continuity

DC volts

DC current

Frequency

Low pass filter

Inrush current mode

18-inch iFlex Flexible Current Probe

Optional

Optional

Included

10-inch iFlex Flexible Current Probe

Optional

Optional

Optional

Functions

Range

373

374

375

376

Current AC

0 to 600.0 A 2% ± 5 counts 2% ± 5 counts 2% ± 5 counts

0 to 999.9 A

2% ± 5 counts

Current DC

0 to 600.0 A

2% ± 5 counts 2% ± 5 counts

0 to 999.9 A

2% ± 5 counts

Voltage AC

0 to 600.0 V 1% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts 1.5% ± 5 counts

Voltage DC

0 to 600.0 V 1% ± 5 counts 1% ± 5 counts 1% ± 5 counts

0 to 1000 V

1% ± 5 counts

Resistance range

0 to 6000 Ω 0 to 6000 Ω 0 to 6000 Ω 0 to 60 kΩ

Jaw opening

32 mm

34 mm

34 mm

34 mm

Max. wire size

750 MCM 750 MCM 750 MCM 750 MCM

Frequency measurement range

500 Hz

500 Hz

Features