Background Image
Previous Page  97 / 164 Next Page
Information
Show Menu
Previous Page 97 / 164 Next Page
Page Background

93

975 AirMeter

Operating temperature

(CO and CO

2

sensors): -20 °C to 50 °C

Operating temperature

(all other functions): -20 °C to 60 °C

Storage temperature:

-20 °C to 60 °C

Humidity:

10% to 90%

Altitude:

Up to 2000 m

975VP

AirMeterVelocity Probe

Recommended Accessories

Shock and vibration:

MIL-PRF-28800F, Class 2

Battery:

Rechargeable Li-Ion (primary), three-

AA (backup)

Weight:

0.544 kg

Size (HxWxD):

28.7 cm x 11.43 cm x 5.08 cm

Data logging:

25,000 records (continuous),

99 records (discrete)

Multilanguage interface:

English, French,

Spanish, Portuguese and German

Two-year warranty

The Fluke 975 AirMeter combines five air

monitoring tools into one, rugged and

easy-to-use handheld tool. Use the Fluke

975 to verify the efficient operation of

heating, ventilation and air conditioning

systems, and test for dangerous carbon

monoxide leaks in all types of buildings.

• Simultaneously measures, logs, and

displays temperature, humidity, CO

2

,

and CO on a bright, backlit LCD display

• One-touch air flow and velocity

measurements with available probe

• Min/Max/Average on all measured and

calculated readings

• Audible and visual threshold alarms

• Multi-language user interface

• Extensive discrete or continuous data

logging capacity, down-loadable to PC

via USB interface

Specifications

(Check the Fluke web for detailed specifications)

Fluke 975

Included Accessories

A4 alkaline batteries (3), Users Manual,

Calibration Cap, FlukeView Forms Software,

Power Adapter, International Power Plugs,

Air Velocity Probe (Fluke 975V only)

Ordering Information

Fluke 975

AirMeter

Fluke 975V

AirMeter with Velocity

975VP

Air Velocity Probe

Feature

Range

Display resolution

Accuracy

Measured specifications

Temperature

-20 °C to 60 °C

0.1 °C

± 0.9 °C from 40 °C to 60 °C

± 0.5 °C from 5 °C to 40 °C

± 1.1 °C from -20 °C to 5 °C

Relative humidity

10 % to 90 % RH non-

condensing

1 %

± 2 % RH (10 % RH

to 90 % RH)

Air velocity

50 fpm to 3000 fpm

0.25 m/sec to 15 m/sec

1 fpm

0.005m/sec

4 % or 4 fpm*

3 % or 0.015 m/sec*

whichever is greater

*Accuracy specification only valid

for velocity readings above 50 fpm.

CO

2

0 to 5000 ppm

1 ppm

Warm up time 1 min

(5 minutes for full specification)

2.75 % + 75 ppm

CO

0 to 500 ppm

1 ppm

± 5 % or ± 3 ppm,

whichever is greater,

@ 20 °C and 50 % RH

Calculated specifications

Dew point temperature

-44 °C to 57 °C

0.1 °C

± 1 °C when temp: -20 °C to 60 °C

RH: 40 % to 90 %

± 2 °C when temp: -20 °C to 60 °C

RH: 20 % to 40 %

± 4 °C when RH: 10 % to 20 %

Wet bulb temperature

-16 °C to 57 °C

0.1 °C

± 1.2 °C when RH: 20 % to 90 %

temp: -20 °C to 60 °C

± 2.1 °C when RH: 10 % to 20 %

Volume flow rate (in a duct)

0 to 3,965 M

3

/m 0 to

140,000 cfm)

0.001 M

3

/min (1 cfm)

N/A:The volume flow

calculation will be a simple average

of the data points times the

duct area

% outside air (based on temperature)

0 to 100 %

0.1 %

N/A

% outside air (based on CO

2

)

0 to 100 %

0.1 %

N/A

Combined inspection tool for complete air

quality inspections