94
922 Airflow Meter
Data Storage:
99 readings
Size (HxWxD):
175 mm x 77.5 mm x 41.9 mm
Weight:
0.64 kg
Battery:
Four AA batteries
Battery Life:
375 hours without backlight,
80 hours with backlight
Two Year Warranty
TPAK
Toolpak
See page 155
Recommended Accessories
Specifications
(Check the Fluke web for detailed specifications)
Fluke 922
Included Accessories
Fluke 922:
Two Rubber Hoses, Wrist Strap, Four
AA Batteries 1.5 V Alkaline, Users Manual and
Soft Carrying Case
Fluke 922 Kit Includes:
Fluke 922 Airflow Meter,
30.48 cm Pitot tube, ToolPak, Two Rubber
Hoses, Wrist Strap, Four AA Batteries 1.5 V
Alkaline, Users Manual and Hard Carrying
Case
Ordering Information
Fluke 922
Air Flow Meter
Fluke 922/Kit
Airflow Meter with
30.48 cm Pitot Tube
General Specifications
Feature
Range
Resolution
Accuracy
Operating Specifications
Air Pressure
± 4000 Pascals
± 16 in H
2
O
± 400 mm H
2
O
± 40 mbar
± 0.6 PSI
1 Pascal
0.001 in H
2
O
0.1 mm H
2
O
0.01 mbar
0.0001 PSI
± 1% +1 Pascal
± 1% + 0.01 in H
2
O
± 1% + 0.1 mm H
2
O
± 1% +0.01 mbar
± 1% + 0.0001 PSI
Air Velocity
250 to 16,000 fpm
1 to 80 m/s
1 fpm
0.001 m/s
± 2.5 % of reading at 10 m/s
(2000 p/min)
Air Flow (Volume)
0 to 99,999 cfm
0 to 99,999 m
3
/hr
0 to 99,999 l/s
1 cfm
1 m
3
/hr
1 l/s
Accuracy is a function of
velocity and duct size
Temperature
0 °C to 50 °C
0.1°C
± 1 % + 2 °C
General specifications
Operating Temperature
0 ºC to +50 ºC
Storage Temperature
-40 ºC to +60 ºC
Operating Relative Humidity
Non condensing (<10 ºC)
90% RH (10 ºC to 30 ºC)
75% RH (30 ºC to 40 ºC)
45% RH (40 ºC to 50 ºC) Without Condensation
IP Rating
IP40
Operating Altitude
2000 m
Storage Altitude
12000 m
EMI, RFI, EMC
Meets requirements for EN61326-1
Vibration
MIL-PREF-28800F, Class 3
Max Pressure at Each Port
10 PSI
Fluke 922/Kit
PT12
PitotTube, 30.48 cm
Measures pressure, air flow and velocity for
maintaining balanced and comfortable
ventilation
The Fluke 922 makes airflow
measurements easy by combining
pressure, air flow, and velocity into a
single, rugged meter. Compatible with
most Pitot tubes, the Fluke 922 allows
technicians to conveniently enter
their duct shape and dimensions for
maximum measurement accuracy.
Use the Fluke 922 to:
Ensure proper air
flow balance and maintain a comfortable
environment; measure pressure drops
across filters and coils; match ventilation
to occupant loads; monitor indoor vs.
outdoor pressure relationships and
manage the building envelope; and
perform duct traversals for accurate
airflow readings.
• Provides differential and static pressure,
air velocity and flow readings
• Convenient colored hoses help you
properly diagnose pressure readings
• Bright, backlit display for clear viewing
in all environments
• Min/Max/Average/Hold functions for
easy data analysis
• Auto power off saves battery life