Background Image
Previous Page  119 / 164 Next Page
Information
Show Menu
Previous Page 119 / 164 Next Page
Page Background

115

1760 Three-Phase Power

Quality Recorder

Topas

Included Accessories

4 x TPS Flex 24-TF-II flexible current probe, 4 x TPS

VoltProbe 600V, 2 GB internal flash memory, ST1760

standard Ethernet cable, RS232 interface cable and

RS232-USB adapter, CS1760 crossover Ethernet cable,

1 mains cable, PC software on CD-ROM, WC17xx

color localization set, GPS-time sync (1760TR only)

CS 1750/1760 carrying bag, hardware and software

manual

Basic models:

Excl. current clamps TPS Flex 24-TF-II

Ordering Information

Fluke 1760 Basic

Power Quality Recorder Topas

Fluke 1760TR Basic Power Quality Recorder Topas

Fluke 1760

Power Quality Recorder Topas

Fluke 1760TR

Power Quality Recorder Topas

The Fluke 1760 Three-Phase Power

Quality Recorder is fully compliant to

IEC 61000-4-30 Class-A, for advanced

power quality analysis and consistent

compliance testing. Designed for analysis

of utility and industrial power distribution

systems, in medium and low-voltage

networks, the Fluke 1760 provides the

flexibility to customize thresholds,

algorithms, and measurement selections.

It has 8 input channels (4 currents/4

voltages or 8 voltages), and captures the

most comprehensive details on user

selectable parameters.

GPS time synchronization:

Correlate

data with events or datasets from other

instruments with precision

Uninterrupted power supply

(40 minutes):

Never miss important

events - even record the beginning and

end of interruptions and outages

10 MHz, 6000 Vpk waveform capture:

Get a detailed picture of even the

shortest event

2 GB data memory:

Enables detailed,

simultaneous recording of numerous

power parameters for long periods of

time

Includes Comprehensive software:

Provides trend diagrams for root cause

analysis, statistical summaries, report

writing and real-time data monitoring

in the online mode

Features

Fluke 1760

(Check the Fluke web for detailed specifications)

The included PQ Analyze software

provides a detailed overview of several

power quality parameters on one

dashboard according to the EN50160

power quality standard.

Power supply:

83 V to 264 V, 45 to 65 Hz

Battery pack:

NIMH, 7.2 V, 2.7 Ah (up to 40 minutes

back-up power supply)

Safety:

600V CAT IV/1000V CAT III

(Rated for use at the service entrance)

Housing:

Fully insulated robust plastic housing

Operating temperature:

0 °C to 35°C

Interfaces:

Ethernet (100 MB/s), RS-232, external

modem via RS-232

Size (HxWxD):

325 mm x 300 mm x 65 mm

Weight:

Approxiamtely 4.9 kg

Two Year Warranty

1760 Basic

1760TR Basic

1760

1760TR

Power quality statistics according to EN50160

Voltage event list (dips, swells and interruptions)

Continuous recording of:

Voltage

Current

Power P, Q, S

Power factor

kWh

Flicker

Unbalance

Frequency

Voltage and current harmonics to the 50th/

Interharmonics

THD

Mains signaling

Triggered recordings

Online mode (Oscilloscope, transients and events)

Fast transient analysis up to 10 MHz

4 voltage probes

4 dual-range flexible current probes (1000 A / 200 A ac)

GPS time sync receiver

Memory

2 GB Flash memory

Recommended Accessories

(Check the Fluke web for complete accessory list)

Model

Description

•TPSVOLTPROBE 10V

10VVoltage Probes (Range: 0.1V to 17V)

•TPSVOLTPROBE 100V

100VVoltage Probes (Range: 1V to 170V)

•TPSVOLTPROBE 400V

400VVoltage Probes (Range: 4V to 680V)

•TPSVOLTPROBE 600V

600VVoltage Probes (Range: 10V to 1000V)

•TPSVOLTPROBE 1 KV

1000VVoltage Probes (Range: 10V to 1700V)

•TPS FLEX 18-TF-II

Flexible Current Probe (Range: 1 A to 100 A / 5 A to 500 A)

•TPS FLEX 24-TF-II

Flexible Current Probe (Range: 2 A to 200 A / 10 A to 1000 A)

•TPS FLEX 36-TF-II

Flexible Current Probe (Range: 30 A to 3000 A / 60 A to 6000 A)

•TPS CLAMP 10 A / 1 A

Clip-on CurrentTransformer (Range: 0.01 A to 1 A / 0.1 A to 10 A)

•TPS CLAMP 50 A / 5A

Clip-on CurrentTransformer (Range: 0.05 A to 5 A / 0.5 A to 50 A)

•TPS CLAMP 200 A / 20 A

Clip-on CurrentTransformer (Range: 0.2 A to 20 A / 2 A to 200 A)

•TPS SHUNT 20 MA

20 mA ac/dc Shunt (Range: 0 to 55 mA)

•TPS SHUNT 5 A

5 A ac/dc Shunt (Range: 0 to 10 A)

Class-A compliance for the most demanding

power quality tests