Background Image
Previous Page  120 / 164 Next Page
Information
Show Menu
Previous Page 120 / 164 Next Page
Page Background

116

Power Quality Current Clamps

Fluke model number

i3000 flex ... 4PK

i400s

i430

FLEXI-TF-II-4PK i5sPQ3

1000A 3210 PR

TF Iflex

Fluke-1730 iFlexi

1500A

12 IN

Fluke-1730

iFlexi 3000A

24 IN

Fluke-1730

iFlexi 6000A

36 IN

Fluke-1730

i40s-EL Clamp-

on Current

Transformer

Description

4 ... phase

3000A Flexible

current clamp set

Single phase

400A current

clamp (4

required)

4 ... phase 3000A

Flexible current

clamp set

3 ... phase

5A Current

clamp set

1000A Single

phase flexible

current clamp

1500 A Single

phase flexible

current clamp

(3 required)

IP 50

3000 A Single

phase flexible

current clamp

(3 required)

IP 50

6000 A Single

phase flexible

current clamp

(3 required)

IP 50

4/40A Current

clamp

(3 required)

Old Fluke model #

3210-PR

n/a

n/a

n/a

n/a

Fluke 1750

Fluke 43X

Fluke 1730

Nominal current

range(s)

30 A

300 A

3000 A

40 A

400 A

3000 A

5 A

1A to 150A,

10A to 1500A

3A to 300A,

30A to 3000A

6A to 600A,

60A to 6000A

40mA to 4A,

0.4A to 40A

Cont. AC current range

1 A ... 30 A

1 A ... 300 A

1 A ... 2400 A

0.5 A ... 40 A

5 A ... 400 A

0.5 A ... 6000 A

0.01 A ... 6 A

0.5A to 1,000A 1A … 150A

10A … 1,500A

1A … 300A

10A … 3,000A

1A … 600A

10A … 6,000A

1A … 150A

10A … 1,500A

Highest current

4000 A

1000 A

100 kA

70 A

1,000A

1,500A

3,000A

6,000A

200A

Lowest measurable

current

1 A

0.5 A

0.5 A

10 mA

0.5A

1A

3A

6A

0.04A

Basic accuracy

(48 ... 65 Hz) 1)

2% + 2 A

2% + 0.15 A

1%

1%

± 1 % of reading

0,70%

0,70%

0,70%

0,50%

Usable frequency

10 Hz ... 100 kHz

5 Hz ... 10 kHz

10 Hz ... 10 kHz

40 Hz ... 5 kHz

40Hz…5kHz

40Hz…5kHz

40Hz…5kHz

40Hz…5kHz

40Hz…5kHz

Requires battery

Flex head length

Clamp opening:

32 mm

61 cm

Clamp opening:

15 mm

61cm

30.5 cm

61 cm

122 cm

n/a

Output level(s)

10 mV/A

1 mV/A

0.1 mV/A

10 mV/A

1 mV/A

0.085 mV/A

@50 Hz

400 mV/A

2mV/A

n/a

n/a

n/a

n/a

Output cable (m)

2,1

2,5

2,5

2,5

3

2

2

2

2

Safety rating

CAT III 600 V

CAT III 1000 V

CAT IV 600 V

CAT III 1000 V

CAT IV 600 V

CAT III 600 V

CATIII 1000V

CAT IV 600V

CATIII 1000V

CAT IV 600V

CATIII 1000V

CAT IV 600V

CATIII 1000V

CAT IV 600V

CATIII 1000V

CAT IV 600V

Connection

4 x BNC

4 x BNC

4 x BNC

3 x BNC

one connector one connector one connector one connector one connector

BNC to banana adapters

included

n/a

n/a

n/a

n/a

n/a

n/a

n/a

n/a

Fluke model number

i1A/10A CLAMP PQ3

i1A/10A

CLAMP PQ4

i5A/50A

CLAMP PQ3

i5A/50A

CLAMP PQ4

i20A/200A

CLAMP PQ3

i20A/200A

CLAMP PQ4

3000/6000A

-TF-4-II

FS17X5-TF-II FS17xx IP65-TF-II

Description

3 ... phase 1A/10A

Mini current clamp

set

4 ... phase

1A/10A

Mini current

clamp set

3 ... phase

5A/50A

Mini current

clamp set

4 ... phase

5A/50A

Mini current

clamp set

3 ... phase

20A/200A

Mini current

clamp set

4 ... phase

20A/2000A

Mini current

clamp set

4 Phase flexiset 4 Phase flexiset,

IP41

4 Phase flexiset,

IP65

Old Fluke model #

CURRENT CLAMPS 1A

(EPO450A)

MBX CLAMP

1A/10A+N

(EPO451A)

MBX CLAMP

5A/50A

(EPO452A)

MBX CLAMP

5A/50A+N

(EPO453A)

MBX CLAMP

20A/200A

(EPO455A)

MBX CLAMP

20/2000A+N

(EPO456A)

MBX Lem Flex

(15/150/3000)

(EP0404A)

MBX Lem Flex

(15/150/3000)

(EP0404A)

Fluke 1735

Fluke 174X

Nominal current

range(s)

1 A

10 A AC

1 A

10 A AC

5 A 50 A AC

5 A 50 A AC

20 A 200 A AC

20 A 200 A AC

30A 300A 3000A

6000A AC

15A 150A 1500A

3000A AC

15A 150A 1500A

3000A AC

Cont. AC current range

10 mA ... 1 A

100 mA ... 10 A

10 mA ... 1 A

100 mA ... 10 A

50 mA ... 5 A

500 mA ... 50 A

50 mA ... 5 A

500 mA ... 50 A

200 mA ... 20 A

2 A ... 200 A

200 mA ... 20 A

2 A ... 200 A

0.8 ... 6.000 A AC

450mA … 15A

600mA… 150A

6A… 1500A

12A… 3000A

450mA … 15A

600mA… 150A

6A… 1500A

12A… 3000A

Highest current

20 A

20 A

100 A

100 A

300 A

300 A

0.8 A

3300 A

3300 A

Lowest measurable

current

10 mA

10 mA

50 mA

50 mA

200 mA

200 mA

450 mA

450 mA

Basic accuracy

(48 ... 65 Hz)

1)

0,50%

0,50%

0,50%

0,50%

0,50%

0,50%

2%+2% position

influence

2%+2% position

influence

Usable frequency

40 Hz ... 10 kHz

40 Hz ... 10 kHz

40 Hz ... 10 kHz

40 Hz ... 10 kHz

40 Hz ... 10 kHz

40 Hz ... 10 kHz

40Hz …5kHz

40Hz …5kHz

Flex head length

92 cm

61 cm

61 cm

Output level(s)

75 mV/A

75 mV/A

15 mV/A

15 mV/A

3.75 mV/A

3.75 mV/A

0.1 mV/A

0.1 mV/A

Output cable (m)

2

2

2

2

2

2

4

2

2

Safety rating

CAT III 600 V

CAT III 600 V

CAT III 600 V

CAT III 600 V

CAT III 600 V

CAT III 600 V

CAT III 1000 V

CAT IV 600V

CAT III 1000 V

CAT IV 600V

CAT III 1000 V

CAT IV 600V

Connection

One connector

One connector

One connector

One connector

One connector

One connector

One connector

One connector

One connector

BNC to banana adapters

included

n/a

n/a

n/a

n/a

n/a

n/a

n/a

n/a

n/a

1)

Basic accuracy: % reading plus floorspec.

n/a = not applicable