117
Norma 4000/5000
Power Analyzers
The compact Fluke Norma Series
Power Analyzers provide the latest
measurement technology to assist
engineers with the development and
testing of motors, inverters, lighting,
power supplies, transformers and
automotive components.
Based on a patented, high-bandwidth
architecture, the instruments deliver
high-precision measurements of single
or three-phase current and voltage,
harmonics analysis, Fast Fourier
Transformation (FFT) analysis, as well as
calculations of power and other derived
values.
A unique user-configurable system
design with plug-in power phases and
other optional modules provides the
flexibility to meet a variety of application
measurement requirements. Recorded
data and waveforms can be viewed
clearly in the large color display and
easily downloaded to a PC for analysis
and report writing.
The Series consists of the Fluke Norma
4000 Three-Phase Power Analyzer and
the Fluke Norma 5000 Six-Phase Power
Analyzer. These rugged analyzers provide
unmatched price performance for easy
and reliable use in the field, or as a bench
unit in laboratories and on test benches.
• Simple user interface ensures easy,
intuitive operation
• Unique user-configurable modular
design
• Simultaneous parallel acquisition of all
phases
• Voltage, current and power harmonics
up to the 40th
• Includes FFT analysis, vector diagram
display, recorder function, and Digital
Oscilloscope (DSO) mode
• User selectable average time – from
15ms to 3600s
• Expandable on-board memory for
storage of measured values
Specifications
(Check the Fluke web for detailed specifications)
Operating temperature:
+ 5 °C to 35 °C
Storage temperature:
- 20 °C to 50 °C
Climatic class:
KYG DIN 40040, maximum
85% relative humidity, non-condensing.
Included Accessories
Power Supply Cable, RS232 Interface and USB
adaptor for Data Download, Fluke NormaView
PC Software, User’s Manual, Test Certificate,
and Calibration Values.
Ordering Information
Fluke Norma 4000 Three-Phase High
Precision Power Analyzer
Fluke Norma 5000 Six-Phase High Precision
Power Analyzer
Fluke Norma Series Power Analyzers
Fast Fourier
Transformation (FFT)
analysis
Fluke Norma 4000
Housing:
Solid metal case
Safety:
EN 61010-1 / 2nd Edition, 1000 V CAT II
(600 V CAT III)
Two Year Warranty
Fluke Norma 4000
Fluke Norma 5000
Number of Phases
1 or 3
3, 4 or 6
Weight
Approx. 5 kg
Approx. 7 kg
Size (HxWxD)
15 cm x 23.7 cm x 31.5 cm
15 cm x 44.7 cm x 31.5 cm
On-board Printer
No
Yes (optional)
Display
Color, 5.7“ / 144 mm - 320 x 240 pixel
Bandwidth
dc to 3 MHz or dc to 10MHz depending on input module
Basic Accuracy
0.2%, 0.1% or 0.03% depending on input modules
Sampling Rate
0.33 MHz or 1 MHz depending on input modules
Voltage Input Range
0.3V to 1000V
Current Input Range (direct, not via shunt)
0.03 mA – 20 A depending on input module
Memory for Configurations
4 MB, expandable to 128 MB
Memory for Settings
0.5 MB
Fast FourierTransformation (FFT)
To the 40th harmonic
RS232 Interface
Standard
PI1 Process Interface (8 analog/impulse inputs and
4 analog outputs)
Optional
IEEE 488.2 /GPIB Interface (1 MBit/s Ethernet /
10 MBit/s or 100 Mbit/s)
Optional
Fluke NormaView PC Software (for data download,
analysis & report writing)
Standard
Fluke Norma 5000
Digital Oscilloscop
(DSO) mode
Vector Display
Recorder function
Reliable, highly accurate measurements for
the test & development of power electronics