106
345
Power Quality Clamp Meter
Fluke 345
Included Accessories
Soft carrying case, Power Log software,
Test probes, Test leads, Alligator clips,
International AC adapter / battery eliminator,
Printed English User manual, Multi-language
manual on CD
Ordering Information
Fluke 345
Power Quality Clamp Meter
View waveforms for equipment
checking and setup
Log parameters over time
to track down intermittent faults
Recommended Accessories
C345
See page 152
TP1-1
See page 146
AC220
See page 147
TP220-1
See page 146
TLK291
See page 146
The Fluke 345 measures a wide range of
electrical parameters for troubleshooting
power disturbances in single- and
three-phase electrical loads. With a
bright color display to see waveforms
and trends, a low-pass filter to remove
high frequency noise, and a high EMC
immunity design, the Fluke 345 is ideal
for measurements on switching loads
such as variable speed drives, electronic
lighting and UPS systems.
•
High safety rating:
600V CAT IV / 1000V
CAT III rated for use at the service
entrance
•
ac/dc current measurements:
Clamp-
on measurement of AC peak and DC
current up to 2000 A without breaking
the circuit
•
Harmonic analysis:
Analyze, display
and log harmonics up to the 30th
harmonic (40th harmonic for 15 Hz to
22 Hz)
•
Verify batteries:
Direct measurement
of DC ripple (%) for battery and DC
systems
Specifications
(Check the Fluke web for detailed specifications)
Power supply:
1.5 V Alkaline AA MN 1500 or IEC LR6
x 6 Battery
Battery life (typical):
>10 hours (backlight on full);
>12 hours (backlight reduced)
Safety:
IEC 61010-1 600 V CAT IV, 1000V CAT III
(maximum input phase-phase 825V rms) double or
reinforced insulation, pollution degree 2
Protection:
IP40; EN60529
Operating temperature:
0 °C to 50 °C
Display:
Color transmissive LCD 320 x 240 pixels
(70 mm diagonal) with 2 level backlight
Digital output:
USB interface to a PC
Size (HxWxD):
300 mm x 98 mm x 52 mm
Jaw opening:
60 mm
Jaw capacity:
58 mm diameter
Weight (including batteries):
0.82 kg
Two Year Warranty
Current measurement
DC, DC rms,AC rms
All measurements DC and 15 Hz to 1 kHz.
Maximum overload 10,000 A or RMS x frequency < 400,000.Amps rms is a true rms
measurement (AC + DC).
Measuring range
0 – 2000 A DC or 1400 AC rms
Harmonics
All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency
range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A
Voltage measurement
DC, DC rms,AC rms
All measurements DC and 15 Hz to 1 kHz. Maximum overload 1,000V rms.Volts rms is a
true-rms measurement (AC + DC).
Measuring range
0 – 825V DC or AC rms
Harmonics
All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz
to 65 Hz;Vacrms > 1V
Watts measurement (single- and three-phase)
DC, DC rms,AC rms
Measuring range
0 – 1650 kW DC or 1200 kW ac
VA measurement (single- and three-phase)
DC, DC rms,AC rms
Measuring range
0 -1650 kVA DC or 1200 kVA ac
VAR measurement (single- and three-phase)
Measuring range
0 – 1250 kVAR
Power factor (single- and three-phase)
Measuring range
0.3 cap…1.0… 0.3 ind (72.5° cap…0°… 72.5° ind)
Displacement power factor
Measuring range
0.3 cap … 1.0 … 0.3 ind (72.5° cap ... 0° ... 72.5° ind)
Kilowatt Hour (kWHr)
Measuring range
40,000 kWHr
Scope function
Time base
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div
Current management:
Ranges
10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000 A
Voltage measurement:
Ranges
4V / 10V / 20V / 40V / 100V / 200V / 400V / 1000V
Inrush current function
All measurements DC and 15 Hz to 1 kHz
Ranges
40, 400 and 2000 A
Memory
Up to 50 screen shots and over 150,000 individual measurement values
The ideal troubleshooting tool for modern