106

345

Power Quality Clamp Meter

Fluke 345

Included Accessories

Soft carrying case, Power Log software,

Test probes, Test leads, Alligator clips,

International AC adapter / battery eliminator,

Printed English User manual, Multi-language

manual on CD

Ordering Information

Fluke 345

Power Quality Clamp Meter

View waveforms for equipment

checking and setup

Log parameters over time

to track down intermittent faults

Recommended Accessories

C345

See page 152

TP1-1

See page 146

AC220

See page 147

TP220-1

See page 146

TLK291

See page 146

The Fluke 345 measures a wide range of

electrical parameters for troubleshooting

power disturbances in single- and

three-phase electrical loads. With a

bright color display to see waveforms

and trends, a low-pass filter to remove

high frequency noise, and a high EMC

immunity design, the Fluke 345 is ideal

for measurements on switching loads

such as variable speed drives, electronic

lighting and UPS systems.

High safety rating:

600V CAT IV / 1000V

CAT III rated for use at the service

entrance

ac/dc current measurements:

Clamp-

on measurement of AC peak and DC

current up to 2000 A without breaking

the circuit

Harmonic analysis:

Analyze, display

and log harmonics up to the 30th

harmonic (40th harmonic for 15 Hz to

22 Hz)

Verify batteries:

Direct measurement

of DC ripple (%) for battery and DC

systems

Specifications

(Check the Fluke web for detailed specifications)

Power supply:

1.5 V Alkaline AA MN 1500 or IEC LR6

x 6 Battery

Battery life (typical):

>10 hours (backlight on full);

>12 hours (backlight reduced)

Safety:

IEC 61010-1 600 V CAT IV, 1000V CAT III

(maximum input phase-phase 825V rms) double or

reinforced insulation, pollution degree 2

Protection:

IP40; EN60529

Operating temperature:

0 °C to 50 °C

Display:

Color transmissive LCD 320 x 240 pixels

(70 mm diagonal) with 2 level backlight

Digital output:

USB interface to a PC

Size (HxWxD):

300 mm x 98 mm x 52 mm

Jaw opening:

60 mm

Jaw capacity:

58 mm diameter

Weight (including batteries):

0.82 kg

Two Year Warranty

Current measurement

DC, DC rms,AC rms

All measurements DC and 15 Hz to 1 kHz.

Maximum overload 10,000 A or RMS x frequency < 400,000.Amps rms is a true rms

measurement (AC + DC).

Measuring range

0 – 2000 A DC or 1400 AC rms

Harmonics

All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); Frequency

range F0 : 15 Hz to 22 Hz and 45 Hz to 65 Hz; Iacrms > 10A

Voltage measurement

DC, DC rms,AC rms

All measurements DC and 15 Hz to 1 kHz. Maximum overload 1,000V rms.Volts rms is a

true-rms measurement (AC + DC).

Measuring range

0 – 825V DC or AC rms

Harmonics

All measurements up to 30th harmonic; Frequency range F0 : 15 Hz to 22 Hz and 45 Hz

to 65 Hz;Vacrms > 1V

Watts measurement (single- and three-phase)

DC, DC rms,AC rms

Measuring range

0 – 1650 kW DC or 1200 kW ac

VA measurement (single- and three-phase)

DC, DC rms,AC rms

Measuring range

0 -1650 kVA DC or 1200 kVA ac

VAR measurement (single- and three-phase)

Measuring range

0 – 1250 kVAR

Power factor (single- and three-phase)

Measuring range

0.3 cap…1.0… 0.3 ind (72.5° cap…0°… 72.5° ind)

Displacement power factor

Measuring range

0.3 cap … 1.0 … 0.3 ind (72.5° cap ... 0° ... 72.5° ind)

Kilowatt Hour (kWHr)

Measuring range

40,000 kWHr

Scope function

Time base

2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms/div

Current management:

Ranges

10 A / 20 A / 40 A / 100 A / 200 A / 400 A / 1000 A / 2000 A

Voltage measurement:

Ranges

4V / 10V / 20V / 40V / 100V / 200V / 400V / 1000V

Inrush current function

All measurements DC and 15 Hz to 1 kHz

Ranges

40, 400 and 2000 A

Memory

Up to 50 screen shots and over 150,000 individual measurement values

The ideal troubleshooting tool for modern