Background Image
Previous Page  111 / 164 Next Page
Information
Show Menu
Previous Page 111 / 164 Next Page
Page Background

107

43B Single-phase Power

Quality Analyzer

The Fluke 43B is the choice for

diagnosing and troubleshooting power

quality and general equipment failures.

Ease to use thanks to menu selection of

the power modes, it combines the

capabilities of a power quality analyzer, a

20 MHz oscilloscope, a multimeter and a

data recorder in a single instrument.

Specifications

(Check the Fluke web for detailed specifications)

Battery life:

Rechargeable Ni-MH pack (charger included), 6 hrs typical (continuous)

Shock & Vibration:

Mil 28800E, Type 3, Class III, Style B.

Operating temperature:

0°C to 50°C; Case: IP51 (dust, drip, waterproof)

Size (HxWxD):

232 mm x 115 mm x 50 mm; Weight: 1.1 kg

Three Years Warranty

Included Accessories

TL224 test lead set, AC220 alligator clip set,

TP4 test probe set, BP120MH rechargeable

battery pack, BB120 shielded BNC adapter,

PM8907 line adapter/charger, i400s AC current

clamp, TP1-1 test probe set, C120 hand

carrying case, OC4USB interface cable, SW43W

FlukeView software, VPS 40 voltage probe, user

and application manual.

Ordening information

Fluke 43B

Power Quality Analyzer

(single-phase)

Recommended Accessories

80TK

See page 150

i1000s

See page 148

i2000flex

See page 148

Fluke 43B

On all inputs

True RMS

Menu items

Measurements

Ranges

Accuracy

Volts/Amps/Hz

Volts

Amps

Mains frequency

CF Crest Factor

5.000V - 1250V

50.00A - 50.00 kA

10 - 400 Hz

1,0 à 10,0

±(1%+10)

±(1%+10)

±(0.5%+2)

±(5%+1)

Power

Watts,VAR,VA

PF, DPF, COS

φ

250 W - 1.56 GW

0.25 - 0.9

0.90 - 1.00

±(4%+4)

±0.04

±0.03

Harmonics

Volts

Amps

Watts

K-factor

1 st to 51 st harmonic

1 st to 51 st

1 st to 51 st

1.0 to 30.0

±(3%+2) to ±(15%+5)

±(3%+8) to ±(15%+5)

±(5%+2) to ±(30%+5)

±10%

Sags & Swells

Voltage and Current

4 min-16 days selectable

±(2%+10)

Transient Capture

40 ns pulse width

Up to 40 transients

Select 20/50/100/200%

above or below line voltage

± 5% of full scale

Inrush Current

1 sec. to 5 min selectable

1 A to 1000 A

± 5% of full scale

Ohms/Continuity/

Capacitance/Range

Ohms

Capacitance

500.0 Ω to 30.00 MΩ

50.00 nF to 500.0 μF

± (0.6%+5)

± (2%+10)

Temperature

(with accessory)

ºC

ºF

-100.0ºC to 400.0ºC

-200.0ºF to 800.0ºF

± (0.5%+5)

Scope

DC,AC,AC+DC, peak,

peak-peak, Hz, duty cycle,

phase, pulse width,

crest factor

Sampling rate:

Bandwidth:

Voltage BW (Channel 1)

Current BW (Channel 2)

25 MS/sec

20 MHz

15 kHz

Screen saves

All functions

20 screens

Recording

V/A/Hz, Power, Harmonics,

Ω/Cap,Temperature, Scope

4 min - 16 days selectable

Select any two parameters

display mode in each

The perfect tool for tracking down

single-phase power-related problems

• Voltage, current, and

power harmonics

• Up to 51st harmonic

• Total harmonic distortion

(THD)

• Phase angle of individual

harmonics

• Watts, power factor,

COS

φ

, VA and VAR

• Voltage and current

waveforms

• Continuously measure

volts and amps on a

cycle-by-cycle basis for up

to 16 days

• Use cursors to read time

and date of sags and

swells

• Connect-and-View™

scope for quick waveform

display

• View voltage and current