Background Image
Previous Page  139 / 164 Next Page
Information
Show Menu
Previous Page 139 / 164 Next Page
Page Background

135

Fluke 28 II Ex

Intrinsically safe True-rms Digital

Multimeter

Now there’s one intrinsically safe digital

multimeter (DMM) you can use in IIC (gas)

Zone 1 and 2 and IIIC (dust) Zone 21 and

22 areas. Whether you work in petroleum,

chemical, or pharmaceutical environments,

all the test and troubleshooting power

you need is packed into the most rugged

intrinsically safe (IS) DMM Fluke has ever

built. The Fluke 28II Ex is also water-proof,

dust-proof and drop-proof.

• ATEX safety rating

II 2 G Ex ia IIC T4 Gb

II 2 D Ex ia IIIC T130 °C Db

I M1 Ex ia I Ma

• CAT III 1000V/CAT IV 600V

electrical safety rating

See also page 28

ATEX-certified Test Tools

Fluke 725Ex

Intrinsically safe Multifunction

Process Calibrator

The Fluke 725Ex intrinsically safe

Multifunction Process Calibrator is powerful

yet easy-to-use. Combined with the

Fluke 700PEx Pressure Modules, the 725Ex

is able to calibrate almost any process

instrument likely to need service in any

area where explosive gases may be present.

• ATEX safety rating II IG EEx ia IIB 171°C

See also page 122

Fluke 707Ex

Fast, one-handed tool for loop checks

The Fluke 707Ex is the ideal, stand alone

tool for calibration and maintenance of 4

to 20 mA control loops. It provides 24V loop

power while measuring mA, and lets you

measure and source/simulate mA with 1 μA

resolution.

• ATEX safety rating II 2G EEx ia IIC T4

See also page 130

Fluke 718Ex

Self-contained Pressure Calibrator

The Fluke 718Ex offers a convenient,

self contained solution for pressure

measurements and calibration. With its

internal pressure sensor and pump, it’s

ready for immediate, stand alone use. The

pressure range can easily be extended to up

to 200 bar with any of the 8 Fluke 700PEx

Pressure Modules.

• ATEX safety rating II IG EEx ia IIC T4

See also page 125

Fluke 700Ex Pressure Modules

These intrinsically safe pressure

modules for use with the Fluke 725Ex

Multifunctional Process Calibrator and

Fluke 718Ex Pressure Calibrator cover the

most commonly used pressure calibration

ranges from 0-25 mbar and 0-200 bar.

There’s a choice of 8 gage, differential and

absolute modules.

• ATEX safety rating

II 1G EEx ia IIC T4

Fluke 568 Ex Intrinsically

safe Infrared thermometer

With a rugged, easy-to-use, ergonomic

design,the Fluke 568 Ex can stand up

to tough industrial,electrical, and

mechanical environments. Meets

intrinsically safe certifications in Class I

Div 1 and Div 2 or Zone 1 and 2

hazardous environments from recognized

safety agencies around the world.

• ATEX safety rating Zone 1 and 2

IECEx EPS 13.0006X Ex ia IIC T4 Gb

See also page 67

Fluke intrinsically safe tools for tough measurement and

calibration tasks

Fluke 28 II Ex

Fluke 707Ex

Fluke 718Ex

Fluke 700Ex

568 Ex

Fluke 725Ex