Background Image
Previous Page  135 / 164 Next Page
Information
Show Menu
Previous Page 135 / 164 Next Page
Page Background

131

771, 772 and 773

mA Process Clamp Meters

Fluke 773

Fluke 771

Included Accessories

Fluke 771:

soft carrying case and user’s manual

Fluke 771 + 772:

plus test leads, AC175 alligator

clip set and TL940 mini-hook test lead set

Ordering Information

Fluke 771

Milliamp Process Clamp Meter

Fluke 772

Milliamp Process Clamp Meter

Fluke 773

Milliamp Process Clamp Meter

Specifications

Features

Size (HxWxD):

771: 212 mm x 59 mm x 38 mm

772 + 773: 248 mm x 76 mm x 41 mm

Weight:

771: 0.26 kg

772 + 773: 0.42 kg

Battery:

771: 2x 1.5V Alkaline, IEC LR6

772 + 773: 4x 1.5V Alkaline, IEC LR6

Battery Life:

771: 20 hours typical

772 + 773: 12 hours @ 12 mA source into

500 ohms

IP Rating:

IP 40

Warranty:

3 years, 1 year on mA clamp

accessory and cable

Fluke 771, 772 and 773

• Measure 4 to 20 mA signals without

“breaking the Loop,” save time and

money troubleshooting 4 to 20 mA

signals

Fluke 772 and 773

• Source 4 to 20 mA signals for testing

control system I/O or I/Ps

• Simulate 4 to 20 mA signals for testing

control system I/O

• Measure 4 to 20 mA signals with in-

circuit measurement

• Power a transmitter with the 24 V loop

power supply

• Automatically ramp and step change

the 4 to 20 mA output for remote

testing

Fluke 773

• DC voltage measurement to verify 24 V

power supplies or voltage I/O signals

• Source DC voltage to test voltage input

devices

• Scaled mA output signal enables a

logging DMM (289) to record 4 to 20 mA

signal without breaking the loop

• mA in/out: simultaneously source a mA

signal while measuring a mA signal

with the clamp

mA measurements without breaking the loop.

Save time. Save money.

Function

Resolution and range Accuracy

Notes

771, 772, 773

mA measurement

0 to 20.99 mA

0.2 % + 5 counts

Measured by clamp

21.0 mA to 100.0 mA 1 % + 5 counts

772 and 773 mA measurement

0 to 24.00 mA

0.2 % + 2 counts

Measured in series

with test jacks

772 and 773 mA source

0 to 24.00 mA

0.2 % + 2 counts

Maximum mA drive:

24 mA into 1,000 ohms

772 and 773 mA simulate

0 to 24.00 mA

0.2 % + 2 counts

Maximum voltage

50 V dc

773

Voltage source

0 to 10.00 V dc

0.2 % + 2 counts

2 mA maximum

drive current

773

Voltage measure

0 to 30.00 V dc

0.2 % + 2 counts

771

772

773

mA measure w/jaw

mA measure In circuit

mA source

mA sim

Loop power 24 V

DCV source 0-10 V

DCV measure 0-30 V

Scaled mA output to mA input

mA in/out

Fluke 772