Background Image
Previous Page  133 / 164 Next Page
Information
Show Menu
Previous Page 133 / 164 Next Page
Page Background

129

709 / 709H

Precision Loop Calibrators

• Best-in-class accuracy at 0.01% reading

• Compact rugged design

• Intuitive user interface with Quick-Set knob for fast setup, easy use

• 24 V DC loop power with mA measure mode (-25% to 125%)

• Resolution of 1 μA on mA ranges and 1 mV on voltages ranges

• Built in selectable 250 Ω resistor for HART communications

• Simple two wire connection for all measurements

• Auto shutdown to conserve battery life

• Variable step and ramp time in seconds

• Valve test (source and simulate defined mA values with % keys

Included Accessories

Two AC175 alligator clips (709)

TL75 test leads (709)

Extended tooth alligator clip set (709H)

75X-8014 stackable lead set (709H)

TP220 test probes (709H)

AC280 SureGrip™ hook clips (709H)

HART cable (709H only)

Soft case

Six AAA batteries (installed)

709/709H Product manual CD-ROM

709/709H Quick reference guide

709/709H Safety information

Ordering Information

Fluke 709 Precision Loop Calibrator

Fluke 709H Precision HART Loop Calibrator

Features

The Fluke 709 and 709H mA loop

calibrators are designed to save time

and produce high-quality results. These

calibrators are built around a user

friendly interface with a Quick-Set rotary

encoder knob. This tool reduces the time

it takes to measure, or source, current

and power up a loop. The protective

holster easily fits into a technician’s

hand and the large backlit display is easy

to read, even in dark, cramped worked

areas.

In addition, the 709H offers:

• Logging of HART data in the field. Once

recorded by the 709H in the field, the

709H/TRACK software can upload the

HART configuration of up to (20) HART

devices in your plant and output data in

either (.csv) or (.txt) format.

• Data logged mA loop measurements

and HART data can be recorded

from a particular transmitter for

troubleshooting and loop tuning.

The data log feature offers selectable

capture with recording intervals of 1

to 60 seconds and a logging capacity of

9800 records or 99 individual sessions.

Each data sample contains the 709H

mA measurement, all four process

variables, and the standard status

conditions.

Fluke reliable. HART compatible.

Functions

mA source, mA simulate, mA read, mA read/loop power, and volts read

Ranges

mA (0 to 24mA) and Volts (0 to 30VDC)

Resolution

1uA on mA ranges and 1mV on voltage range

Accuracy

0.01% +/- 2 counts all ranges (@23° +/- 5°C)

Operating temperature Range

-10 °C to 55 °C

Humidity range

10 to 95% non-condensing

Stability

20ppm of F.S. /°C from -10°C to 18°C and 28°C to 55°C

Display

128 x 64 pixels, LCD Graphic w/backlight, .34” high digits

Loop Compliance Voltage

24VDC @ 20mA

Over-Voltage Protection

240VAC

Overload Current Protection

28mA DC

EMC

EN61326 Annex A (Portable Instruments)

Specifications

Power:

6 AAA alkaline

Dimensions (HxWxD):

150 x 90 x 30 mm

Battery life:

≥ 40 hours continuous use

(measure mode using alkaline)

Weight:

0.3 kg

Warranty:

Three years

Recommended Accessories

709H Track Software/cable

Fluke 709/709H