126
721 Precision Dual Pressure Calibrator
Low pressure sensor
High pressure sensor
Model number / ordering information
Range 1
Resolution
Accuracy
Range 2
Resolution
Accuracy
Fluke-721-1601
Dual Sensor Pressure Calibrator
-970mbar to 1.1 bar
0.0001 bar
0.025% of range -830mbar to 6.9 bar
0.0001 bar
0.025% of range
Fluke-721-1603
Dual Sensor Pressure Calibrator
-970mbar to 1.1 bar
0.0001 bar
0.025% of range
-830mbar to 20 bar
0.001 bar
0.025% of range
Fluke-721-1605
Dual Sensor Pressure Calibrator
-970mbar to 1.1 bar
0.0001 bar
0.025% of range -830mbar to 34.5 bar
0.001 bar
0.025% of range
Fluke-721-1610
Dual Sensor Pressure Calibrator
-970mbar to 1.1 bar
0.0001 bar
0.025% of range
0.00 bar to 69 bar
0.001 bar
0.025% of range
Fluke-721-1615
Dual Sensor Pressure Calibrator
-970mbar to 1.1 bar
0.0001 bar
0.025% of range
0.00 bar to 103 bar
0.01 bar
0.025% of range
Fluke-721-1630
Dual Sensor Pressure Calibrator
-970mbar to 1.1 bar
0.0001 bar
0.025% of range
0.00 bar to 200 bar
0.01 bar
0.025% of range
Fluke-721-1650
Dual Sensor Pressure Calibrator
-970mbar to 1.1 bar
0.0001 bar
0.025% of range
0.00 bar to 345 bar
0.01 bar
0.035% of range
Fluke-721-3601
Dual Sensor Pressure Calibrator
-970mbar to 2.48 bar
0.0001 bar
0.025% of range -830mbar to 6.9 bar
0.0001 bar
0.025% of range
Fluke-721-3603
Dual Sensor Pressure Calibrator
-970mbar to 2.48 bar
0.0001 bar
0.025% of range
-830mbar to 20 bar
0.001 bar
0.025% of range
Fluke-721-3605
Dual Sensor Pressure Calibrator
-970mbar to 2.48 bar
0.0001 bar
0.025% of range -830mbar to 34.5 bar
0.001 bar
0.025% of range
Fluke-721-3610
Dual Sensor Pressure Calibrator
-970mbar to 2.48 bar
0.0001 bar
0.025% of range
0.00 bar to 69 bar
0.001 bar
0.025% of range
Fluke-721-3615
Dual Sensor Pressure Calibrator
-970mbar to 2.48 bar
0.0001 bar
0.025% of range 0.00 bar to 103.4 bar
0.01 bar
0.025% of range
Fluke-721-3630
Dual Sensor Pressure Calibrator
-970mbar to 2.48 bar
0.0001 bar
0.025% of range
0.00 bar to 200 bar
0.01 bar
0.025% of range
Fluke-721-3650
Dual Sensor Pressure Calibrator
-970mbar to 2.48 bar
0.0001 bar
0.025% of range
0.00 bar to 345 bar
0.01 bar
0.035% of range
Fluke-720RTD
RTD probe for Fluke 721 and 719Pro
Fluke-720URTDA
Universal RTD adapter for Fluke 721 and 719Pro
Fluke 71XTrap
Liquid and dirt trap for Fluke 718, 719 and 719Pro
The Fluke 721 Precision Pressure
Calibrator with dual isolated pressure
sensors is the ideal tool for gas custody
transfer applications allowing you to
take simultaneous static and differential
pressure measurements with a single
tool.
The 721 can be configured by selecting
either a 1.1 bar or 2.48 bar low pressure
sensor then add any of 7 high pressure
ranges including 6.9, 20, 24.5, 69, 103.4,
200, 345 bar.
• Ideal for gas flow calibration
(custody transfer) applications
• Two isolated, stainless steel, pressure
sensors with 0.025 % accuracy
Pressure calibration and temperature
measurement for custody transfer
applications
• Pt100 RTD input for temperature
measurement, (probe optional)
• Measures 4 to 20 mA signals
• Internal 24 V loop power supply can
power a transmitter under test
• Measure up to 30 V DC,
chec 24 V loop power supplies
• Extend pressure measurement range
with connection to external 700 series
pressure modules (29 ranges)
• Large backlit graphic display can display
up to three inputs simultaneously
• Store five instrument setups for recall
and use
EMC:
EN50082-1:1992 and EN55022:1994 Class B
Fluke 721:
All media compatible with 316SS
Battery:
4 standard AA alkaline batteries
Three year warranty
Supported Pressure Units;
psi, in. H
2
O(4°C),
in. H
2
O(20°C), cm H
2
O(4°C), cm H
2
O(20°C),
bar mBar, kPa, inHg, mmHg, kg/cm
2
Max Voltage:
30V
Operating temperature:
-10°C to 50°C
Safety:
CSA C22.2 No. 1010.1:1992
Specifications
(Check the Fluke web for detailed specifications)
Fluke 721