Background Image
Previous Page  131 / 164 Next Page
Information
Show Menu
Previous Page 131 / 164 Next Page
Page Background

127

787/789 ProcessMeters

Included Accessories

787:

Yellow Holster (H80M excl. TPAK), Hard

Point Test Lead Set plus AC175 Alligator Clips,

one 9V battery, user manual

789:

Test Lead Set plus AC175 Alligator Clips,

four 9V AA alkaline batteries, user manual and

quick reference guide.

Ordering Information

Fluke 787 ProcessMeter

Fluke 789 ProcessMeter

FVF-SC2

FlukeView Forms Software

including interface cable

Features

Maximum voltage:

1000 V

Operating temperature:

-20 to 55ºC

787

Size (HxWxD):

201 mm x 98 mm x 52 mm

Weight:

0.642 kg

Battery:

One 9 V alkaline

Battery life:

12 to 50 hours typical

Three Year Warranty

789

Size (HxWxD):

203 mm x 100 mm x 50 mm

Weight:

0.6 kg

Battery:

Four AA alkaline batteries

Battery life:

14 to 140 hours typical

Three Year Warranty

The Fluke 787 and 789 ProcessMeters

combine a Digital Multimeter and a Loop

Calibrator in one rugged handheld tool,

giving process technicians double the

power.

The Fluke 789 has a built-in 24 V loop

supply which reduces the need for taking

a separate power supply when doing

offline transmitter testing.

The IR communication port of the Fluke

789 allows data to be logged to optional

FlukeView Software for graphical analysis

and reporting.

Double your power

Recommended Accessories

ir3000 FC

See page 155

TL220-1

See page 145

80T-150U

See page 150

i400

See page 148

i410

See page 149

Specifications

True RMS

787 789

DMM and Loop Calibrator in one tool

● ●

Precision 1000 V, 440 mA True RMS Digital Multimeter

● ●

DC current source and Loop Calibrator

● ●

24 V Loop power supply

Min/Max / Average / Hold / Relative Modes

● ●

Diode Test and Continuity Beeper

● ●

Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp

● ●

Simultaneous mA and % of scale read-out

● ●

Externally accessible battery / fuses

/-

/

HART mode setting with loop power and a built-in 250 Ω resistor

0% and 100% buttons to toggle between 4 and 20 mA sourcing for a quick span check

Infrared I/O serial port

787

789

Voltage measurements

Range

0-1000 V AC or DC

0-1000 V AC or DC

Resolution

0.1 mV to 1.0 V

0.1 mV to 1.0 V

Accuracy

0.1% Rdg+1 LSD (V DC)

0.1% Rdg+1 LSD (V DC)

Other specifications

Max drive capability

500 Ω

1200 Ω

Loop power

N/A

24 V

Resistance measurement

To 40 MΩ, 0.2%+1 LSD

To 40 MΩ, 0.2%+1 LSD

Frequency

To 19.999 kHz, 0.005%+1 LSD

To 19.999 kHz, 0.005%+ LSD

Continuity

Beeps for resistance < 100 Ω

Beeps for resistance < 100 Ω

Span Check

No

Yes

Current measurement

Range

0-1 A

0-30 mA

0-1 A

0-30 mA

Resolution

1 mA

0.001 mA

1 mA

0.001 mA

Accuracy

0.2%+2 LSD

0.05%+2 LSD

0.2%+2 LSD

0.05%+2 LSD

Current Sourcing

Range

0-20 mA or 4-24 mA

0-20 mA or 4-24 mA

Accuracy

0.05% of span

0.05% of span

For more information on Fluke Connect

see pages 13-18

Fluke 789

Fluke 787