www.fluke.com/accessory 92 Accessories Fluke ac current clamps i200s i400s i800 i1000s i200 i200s i400 i400s i800 i1000s i3000s i2000 Flex i3000s Flex i6000s AC current range 1 A to 200 A 1 A to 200 A 1 A to 400 A 0.5 A to 400 A 1 A to 800 A 0.2 A to 1000 A 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 60 A to 6000 A Accuracy < 3 % + 0.5 A 48 Hz to 65 Hz < 1 % + 0.5 A 48 Hz to 65 Hz 2 % + 0.06 A 45 Hz to 400 Hz .5 A to 40 A, 2 % + .015 A, 5 A to 400 A, 2 % + .04 A, 45 Hz to 400 Hz 0.1 A to 10 A ± 3 % + .01 A, 10 A to 200 A ± 2 %, 200 A to 800 A ± 1 % 0.2 to 10 A: 3 % + 0.1 A 10 A to 100 A: 2 % + 0.5 A 100 A to 1000 A: 1 % + 1 A 48 Hz to 65 Hz 1 to 30 A: 2 % + 0.1 A 1 to 300 A: 2 % + 0.5 A 1 to 3000 A: 2 % + 2 A 48 Hz to 65 Hz ± 1 % of range 45 Hz to 65 Hz Ranges: 20 A, 200 A, 2000 A ± 1 % of range, 45 Hz to 65 Hz Ranges: 30 A, 300 A, 3000 A ± 1 % of range 45 Hz to 65 Hz Bandwidth (-3 dB) 40 Hz to 40 kHz 40 Hz to 40 kHz 5 kHz to 20 kHz 5 Hz to 10 kHz 30 Hz to 10 kHz (typical) 5 Hz to 100 kHz 10 Hz to 100 kHz 10 Hz to 20 kHz 10 Hz to 50 kHz 10 Hz to 50 kHz, (- 3 dB) Maximum conductor diameter 20 mm (0.8 in) 20 mm (0.8 in) 32 mm (1.25 in) 32 mm (1.25 in) 54 mm (2.13 in) 54 mm (2.13 in) 64 x 100 mm (2.52 x 3.94 in) 177 mm (7 in) 177 mm (7 in) or 265 mm (10.4 in) 193 mm (7.6 in) or 289 mm (11.4 in) Maximum conductor size 150 mm2 150 mm2 400 mm2 400 mm2 2x 240 mm² or 1x 500 mm² 2x 240 mm² or 1x 500 mm² 64 mm (2.52 in) 610 mm (24 in) circumference 610 mm or 915 mm circumference 610 mm (24 in) or 915mm (36 in) Output levels 1 mA/A 10 mV/A 100 mV/A 1 mA/A 10 mV/A 1 mV/A 1 mA/A 1 mV/A 10 mV/A 100 mV/A 10 mV/A 1 mV/A 0.1 mV/A 100 mV/A 10 mV/A 1 mV/A 100 mV/A 10 mV/A 1 mV/A 50 mV/A 5 mV/A 0.5 mV/A Output cable 1.5 m shrouded banana plugs 2 m to BNC termination 1.5 m shrouded banana plugs 2.5 m to BNC termination 1.6 m shrouded banana plugs 1.6 m to BNC termination 2.1 m to BNC termination 2 m with double shrouded banana plugs 2.1 m to BNC termination 2 m to BNC, 4 mm plug adapter supplied Warranty One-year One-year One-year One-year One-year One-year One-year One-year One-year One-year Safety rating CAT III 600 V CAT III 600 V CAT III 1000 V CAT IV 600 V CAT III 1000 V CAT IV 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V CAT III 600 V i2000/i3000s/i6000s Flex i3000s i200 i200s i400 i400s i800 i1000s i3000s i2000 Flex1 i3000s Flex 114/116 1 A to 200 A 0.6 A to 400 A* 0.6 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 115/117 60 A to 200 A 1 A to 200 A 60 A to 400 A 0.6 A to 400 A* 60 A to 800 A 0.6 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 233 60 A to 200 A 1 A to 200 A 60 A to 400 A 0.6 A to 400 A* 60 A to 800 A 0.6 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 27II 2 A to 200 A 1 A to 200 A 2 A to 400 A 1 A to 400 A* 2 A to 800 A 0.1 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 28II 1.8 A to 200 A 1 A to 200 A 1.8 A to 400 A 1.8 A to 400 A 1.8 A to 800 A 0.2 A to 1000 A* 2 A to 3000 A 2 A to 2000 A 3 A to 3000 A 77 IV 1 A to 200 A 1 A to 400 A* 0.1 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 175/177/179 3 A to 200 A 1 A to 200 A 3 A to 400 A 1 A to 400 A* 3 A to 800 A 0.3 A to 1000 A* 3 A to 3000 A 2 A to 2000 A 3 A to 3000 A 1577/1587 Insulation Meter 3 A to 200 A 1 A to 200 A 3 A to 400 A 3 A to 400 A* 3 A to 400 A 0.3 A to 1000 A* 3 A to 3000 A 2 A to 2000 A 3 A to 3000 A 83V/88V 2 A to 200 A 1 A to 200 A 2 A to 400 A 1 A to 400 A* 2 A to 800 A 0.1 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 87V 2 A to 200 A 1 A to 200 A 2 A to 400 A 2 A to 400 A* 2 A to 800 A 0.2 A to 1000 A* 2 A to 3000 A 2 A to 2000 A 3 A to 3000 A 287/289 1 A to 200 A 1 A to 200 A 1 A to 400 A 0.5 A to 400 A* 1 A to 800 A 0.2 A to 1000 A* 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 43B Power Quality Analyzer 1 A to 200 A 0.35 A to 400 A 0.1 A to 1000 A 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 434/435 Power Quality Analyzer 1 A to 200 A 1.2 A to 400 A 0.3 A to 1000 A 1.2 A to 3000 A i430Flex-TF-II i430Flex-TF-II 120 Series ScopeMeters 1 A to 200 A 2.5 A to 400 A 0.25 A to 1000 A 2.5 A to 3000 A 2 A to 2000 A 3 A to 3000 A 190 Series ScopeMeters 1 A to 200 A 1 A to 400 A 0.1 A to 1000 A 1 A to 3000 A 2 A to 2000 A 3 A to 3000 A 8808A 1 A to 200 A 1 A to 200 A 1 A to 400 A 0.5 A to 400 A* 1 A to 800 A 0.1 A to 1000 A* 1 A to 3000 A 2 A to 2000 A* 3 A to 3000 A* 8845A/8846A 1 A to 200 A 1 A to 200 A 1 A to 400 A 1 A to 400 A* 1 A to 800 A 0.2 A to 1000 A* 1 A to 3000 A 2 A to 2000 A* 3 A to 3000 A* 787/789 Process Meters 50 A to 200 A 1 A to 200 A 50 A to 400 A 2 A to 400 A* 50 A to 440 A 0.2 A to 1000 A* 2 A to 3000 A 2 A to 2000 A 3 A to 3000 A * Requires PM9081/001 Adapters. 1 Three range version. 2 Current and watt readings will be multiples of 10 higher or lower than actual on some ranges. AC current clamp specifications AC current clamp selection guide i200 i400 i2000 Flex, i3000s Flex-24 (24 in dia), i3000s Flex-36 (36 in dia), i6000s Flex-24 (24 in dia), i6000s Flex-36 (36 in dia)