57 Fluke 715, 707 and 705 Loop Calibrators Delivers outstanding performance, durability and reliability Fluke 715 Loop Calibrator The Fluke 715 Volt/mA Calibrator can measure loop current as well as voltage output. • Source voltage to 200 mV or 20 V • Measure loop current (0-20 mA, 4-20 mA) signals with 0.01 % accuracy and 1 µA resolution • Measure voltage output process signals from PLCs, transmitters • Source or simulate 4-20 mA loop current • 24 V loop supply with simultaneous current measurement • Ramp and Step Ramp output functions Fluke 707 and 705 Loop Calibrators With large displays and simple interface, the Fluke 707 and 705 provide easy to use, one-hand operation. • Innovative output adjustment dial on 707 for 1 μA and 100 μA resolution • Simultaneous mA and % readout for quick, easy interpretation of readings • mA accuracy of 0.015 % on the Fluke 707 and 0.02 % on the 705 • HART™ mode on 707 connects 250 ohm resistor in series with 24 V loop for compatibility with HART communicators • Push button 25 % steps for fast, easy linearity checks • “Span Check” for fast confirmation of zero and span • Selectable slow and fast linear step ramp provide ramping outputs for valve slewing, remote testing and loop functional tests • 24 V internal loop supply, so you can power and read a transmitter at the same time without carrying a DMM • 0-20 mA or 4-20 mA default start up modes Specifications Functions Fluke 705 and 707 Fluke 715 Voltage measurement Range 0 V to 28 V 0 mV to 200 mV 0 V to 25 V Resolution 1 mV 10 µV 1 mV Accuracy 705: 0.025 % Rdg + 1 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD 0.01 % Rdg + 2 LSD Current measurement Range 0 mA to 24 mA 0 mA to 24 mA Resolution 0.001 mA 0.001 mA Accuracy 705: 0.02 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD 0.01 % + 2 LSD Current sourcing Range 0 mA to 20 mA or 4 mA to 20 mA 0 mA to 20 mA or 4 mA to 20 mA Accuracy 705: 0.025 % Rdg + 2 LSD 707, 707Ex: 0.015 % Rdg + 2 LSD 0.01 % Rdg + 2 LSD Drive capability 705: 1000 W @ 24 mA 707: 1200 W @ 24 mA 707Ex: 700 W @ 20 mA 1000 W @ 24 mA Loop power while measuring mA 24 V 24 V Voltage sourcing 0 mV to 200 mV or 0 V to 20 V Display current and % of span • mA or % Auto step, auto ramp • • Span Check • • Battery life 18 hours typical at 12 mA 18 hours typical at 12 mA Warranty Three-year Instrument CarePlan Ordering information Models Included accessories FLUKE-715 Volt/mA Calibrator Test leads, alligator clips, holster, traceable calibration report and data, single 9 V alkaline battery, instruction sheet (14 languages) FLUKE-707 Loop Calibrator FLUKE-705 Loop Calibrator Fluke loop calibrators are reliable and accurate. The 709H adds basic HART communication (see page 58). Process Calibration Tools www.fluke.com/loop PROCESS CALIBRATION TOOLS