www.fluke.com/accessory 93 Accessories i410 i310s i30s i30 Fluke ac/dc current clamps 80i-110s i410 i1010 i30 i30s i310s DC range 0.1 A to 100 A 1 A to 400 A 1 A to 1000 A 30 mA to 30 A 30 mA to 30 A 0.1 A to 450 A AC range 0.1 A to 70 A 1 A to 400 A 1 A to 600 A 30 mA to 20 A rms 30 mA to 20 A rms 0.1 A to 300 A Accuracy 0.1 A to 10 A; dc to 1 kHz: ± 3 % + 50 mA; up to 100 A add 15 %; up to 20 kHz add 12 % 3.5 % + 0.5 A for dc or ac (45 to 400 Hz) 2 % + 0.5 A for dc or ac (45 to 400 Hz) ± 1 % of reading, ± 2 mA ± 1 % of reading, ± 2 mA 30 A range: 1 % + 50 mA 300 A range: 1 % + 300 mA Bandwidth (-3 dB) 100 kHZ 3 kHz 10 kHz dc to 20 kHz (-0.5 dB) dc to 100 kHz (-0.5 dB) dc to 20 kHz Zero error adjustment • • • • • • Maximum conductor diameter 11.8 mm (0.46 in) 30 mm (1.18 in) 30 mm (1.18 in) 19 mm (0.75 in) 19 mm (0.75 in) 19 mm (0.75 in) Maximum conductor size 35 mm2 1x 400 mm² or 2x 240 mm² 1x 400 mm² or 2x 240 mm² 120 mm² 120 mm² 120 mm² Output levels 10 mV/A, 100 mV/A 1 mV/A 1 mV/A 100 mV/A 100 mV/A 1 mV/A, 10 mV/A Output cable 1.6 meter with BNC termination 1.2 meter with shrouded banana plugs 1.2 meter with shrouded banana plugs 1.5 meter with shrouded dual banana plugs 2 meter with BNC termination 2 meters with BNC termination and a BNC to safety shrouded banana adapter Battery life 40 hours 60 hours 60 hours 30 hours 30 hours 30 hours Warranty One-year One-year One-year One-year One-year One-year Safety CAT II 600 V; CAT III 300 V CAT III 600 V CAT III 600 V CAT III 300 V CAT III 300 V CAT III 300 V 80i-110s i410 i1010 i30 i30s i310s 114/115/116/117 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1.4 A to 400 A dc/ 6 A to 400 A ac 1.4 A to 1000 A dc/ 6 A to 600 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 0.1 A to 450 A dc/ 0.6 A to 300 A ac 233 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1.4 A to 400 A dc/ 6 A to 400 A ac 1.4 A to 1000 A dc/ 6 A to 600 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 0.1 A to 450 A dc/ 0.6 A to 300 A ac 27II 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 1 A to 400 A ac 1 A to 1000 A dc/ 1 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.1 A to 300 A ac 28II 0.1 A to 100 A dc/ 0.2 A to 70 A ac* 1 A to 400 A dc/ 6 A to 400 A ac 1 A to 1000 A dc/ 6 A to 600 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 30 mA to 30 A dc/ 60 mA to 20 A ac 0.1 A to 450 A dc/ 2 A to 300 A ac 77-IV 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 5 A to 400 A ac 1 A to 1000 A dc/ 5 A to 600 A ac 30 mA to 30 A dc/ 40 mA to 20 A ac 30 mA to 30 A dc/ 40 mA to 20 A ac 0.1 A to 450 A dc/ 0.4 A to 300 A ac 175/177/179 0.11 A to 100 A dc/ 0.3 A to 70 A ac* 1.6 A to 400 A dc/ 30 A to 400 A ac 1.6 A to 1000 A dc/ 30 A to 600 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 0.1 A to 450 A dc/ 3 A to 300 A ac 1577/1587 FC Insulation Meter 0.1 A to 100 A dc/ 0.3 A to 70 A ac* 1.2 A to 400 A dc/ 30 A to 400 A ac 1.2 A to 1000 A dc/ 30 A to 600 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 30 mA to 30 A dc/ 300 mA to 20 A ac 0.1 A to 450 A dc/ 3 A to 300 A ac 83V/88V 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 1 A to 400 A ac 1 A to 1000 A dc/ 1 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.1 A to 300 A ac 87V 0.1 A to 100 A dc/ 0.2 A to 70 A ac* 1 A to 400 A dc/ 20 A to 400 A ac 1 A to 1000 A dc/ 20 A to 600 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 0.1 A to 450 A dc/ 2 A to 300 A ac 287/289 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 1 A to 400 A ac 1 A to 1000 A dc/ 1 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.1 A to 300 A ac 123/124 ScopeMeters 0.1 A to 100 A dc/ 0.25 A to 70 A ac 1 A to 400 A dc/ 25 A to 400 A ac** 1 A to 1000 A dc/ 25 A to 600 A ac** 30 mA to 30 A dc/ 250 mA to 20 A ac 0.1 A to 450 A dc/ 2.5 A to 300 A ac 190 Series ScopeMeters 0.1 A to 100 A dc/ 0.1 A to 70 A ac 1 A to 400 A dc/ 5 A to 400 A ac** 1 A to 1000 A dc/ 5 A to 600 A ac** 30 mA to 30 A dc/ 50 mA to 20 A ac** 30 mA to 30 A dc/ 50 mA to 20 A ac 0.1 A to 450 A dc/ 0.5 A to 300 A ac 8808A 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 2 A to 400 A ac 1 A to 1000 A dc/ 2 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.2 A to 300 A ac 8845A/8846A 0.1 A to 100 A dc/ 0.1 A to 70 A ac* 1 A to 400 A dc/ 1 A to 400 A ac 1 A to 1000 A dc/ 1 A to 600 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 30 mA to 30 A dc/ 30 mA to 20 A ac 0.1 A to 450 A dc/ 0.1 A to 300 A ac 705/707 0.1 A to 100 A dc, no ac* 4 A to 400 A dc, no ac 4 A to 1000 A dc, No ac 40 mA to 30 A dc, no ac 40 mA to 30 A dc, no ac 0.4 A to 450 A dc, no ac 715 0.1 A to 100 A dc, no ac* 4 A to 400 A dc, no ac 4 A to 1000 A dc, No ac 40 mA to 30 A dc, no ac 40 mA to 30 A dc, no ac 0.1 A to 450 A dc, no ac 787/789 Process Meters 0.1 A to 100 A dc/ 0.2 A to 70 A ac* 1 A to 400 A dc/ 20 A to 400 A ac 1 A to 1000 A dc/ 20 A to 600 A ac 30 mA to 30 A dc/ 200 mA to 20 A ac 3 mA to 30 A dc/ 200 mA to 20 A ac 0.1 A to 450 A dc/ 2 A to 300 A ac * Requires PM9081 Adapter ** Requires PM9082/001 Adapter AC/DC current clamp specifications AC/DC current clamp selection guide 80i-110s i1010 i310s, i30s and i30 Hall Effect AC/DC Current Clamps Especially useful for low current measurements down to 30 milliamps.