42 www.fluke.com/iaq Indoor Air Quality Tools Fluke RLD2 UV Refrigerant Leak Detector Flashlight Flashlight that uncovers refrigerant leaks instantly. Laser pointer to find exact leak location. CO-220 Carbon Monoxide Meter Check CO levels around furnaces and boilers. Tracks increasing frequency as CO levels rise. CO-205 Aspirator Kit A flue gas sampling accessory kit. Ordering information Models Included accessories FLUKE-975V AirMeter™ with Velocity Calibration cap, air velocity probe (Fluke 975V only), FlukeView® Forms software, power adapter, international power plugs, hard carrying case, three AA alkaline batteries, users manual with safety information FLUKE-975 AirMeter™ FLUKE-922 Airflow Meter Two rubber hoses, soft carrying case, four AA alkaline batteries 1.5 V, users manual FLUKE-922/Kit Airflow Meter Kit 12 inch pitot tube, two rubber hoses, magnetic hanging strap, four AA alkaline batteries, users manual, hard carrying case FLUKE-RLD2 Refrigerant Leak Detector Flashlight FLUKE-CO-220 Carbon Monoxide Meter FLUKE-CO-205 Aspirator Kit Specifications Range Accuracy Air pressure ± 4000 Pascals/± 16 in H2O/± 400 mm H2O/ ± 40 mbar/± 0.6 PSI ± 1 % + 1 Pascal/± 1 % + 0.01 in H2O/ ± 1 % + 0.1 mm H2O/± 1 % + 0.01 mbar/ ± 1 % + 0.0001 PSI Air velocity 250 fpm to 16,000 fpm (1 to 80 m/s) ± 2.5 % of reading at 2000 fpm (10.00 m/s) Air flow (volume) 0 to 99,999 cfm; 0 to 99,999 m 3/hr; 0 to 99,999 l/s Accuracy is a function of velocity and duct size Temperature 0 °C to 50 °C (32 °F to 122 °F) 0.1 °C (0.1 °F) Data storage 99 readings Fluke 975 AirMeter™ Simple, all-in-one air diagnostics The Fluke 975 AirMeter™ combines five powerful air quality tools into one. • Simultaneously measures, logs and displays temperature, humidity, CO2 and CO • % of outside air calculation, one-touch air flow and velocity with available probe (975V) • Dew point and wet bulb temperature • CO2 and CO field calibration feature • Min/Max/Avg on all measured and calculated readings, audible and visual threshold alarms • Discrete or continuous data logging capacity, downloadable to PC via USB interface • Automatically compensates for barometric pressure changes • Two-year warranty Fluke 922 Airflow Meter/Micromanometer The Fluke 922 makes your job easier by combining differential pressure, airflow and velocity into a single, rugged meter. • Measures differential and static pressure, air velocity and flow readings • User-defined duct shape and size for maximum airflow accuracy • Min/Max/Avg/Hold functions Instrument CarePlan INDOOR AIR QUALITY TOOLS Specifications Range Display resolution Accuracy Temperature -20 °C to 50 °C (-5 °F to 122 °F) 0.1 °C (0.1 °F) ± 0.9 °C/± 1.62 °F from 40 °C to 60 °C ± 0.5 °C/± 1.00 °F from 5 °C to 40 °C ± 1.1 °C/± 1.98 °F from -20 °C to 5 °C Relative humidity 10 % to 90 % RH non-condensing 1 % ± 2 % RH (10 % RH to 90 % RH) Air velocity 50.0 fpm to 3000 fpm 0.25 m/s to 15 m/s 1 fpm (0.005 m/s) ± 4 % or 4 fpm* ± 4 % or 0.02 m/s* whichever is greater * Accuracy specification only valid for velocity readings above 0.25 m/s CO2 0 ppm to 5000 ppm 1 ppm Warm up time 1 min (5 minutes for full specification) 2.75 % + 75 ppm CO 0 ppm to 500 ppm 1 ppm ± 5 % or ± 3 ppm, whichever is greater, @ 20 °C and 50 % RH