Page Background

Fluke 714B

Fluke 712B

124

712B / 714B

Temperature Calibrators

Included Accessories

Magnetic hanging tool, batteries, manual,

traceable calibration certificate, and test leads

Ordering Information

Fluke 712B RTD Temperature Calibrator

Fluke 714B TC Temperature Calibrator

Features

The new Fluke 712B and 714B are

designed for both simplicity-ease of use

and high accuracy. They are a powerful

combination of temperature and loop

calibration.

For the customer that does not want

the complexity that a multifunction test

tool brings yet demands high accuracy

for temperature calibration, these new

calibrators deliver.

Accuracy and simplicity

Recommended Accessories

700TC1

See page 151

80PK-10

See page 150

80PK-8

See page 150

The 712B can measure and simulate (13) different RTD types and resistance

The 714B can measure and simulate (17) different thermocouple types and millivolts

Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal

Hanging tool designed in and included with every unit

Configurable 0 % and 100 % source settings for quick 25 % linearity checks

Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings

Dual inputs and backlit display for easy interpretation of measurements

Power down settings remembered at power up for easy restart of tests

1-year and 2-year specifications and traceable certificate of calibration

Specifications

General specifications

712B

714B

Operating temperature

-10 °C to 50 °C

Operating altitude

2,000 meters

Relative humidity

(% RH operating without

condensation)

Non condensing

90 % (10 °C to 30 °C)

75 % (30 °C to 40 °C)

45 % (40 °C to 50 °C)

(Without condensation)

Vibration requirements

MIL-T-28800E, Class 2

Drop text requirements

1 meter

IP Rating

IEC 60529: IP52

Safety

IEC 61010-1, Max 30 V to earth, Pollution Degree 2

Power supply

4 AA NEDA 1.5A IEC LR6 batteries

DC mA measurement

Resolution

0-24 mA

Range

0.001 mA

Accuracy (% of reading + counts)

0.010 % + 2 μA

Ohms measurement

Ohms range

0.00 Ω to 400.00 Ω,

400.0 Ω to 4000.0 Ω

Accuracy (% of reading +counts)

0.015 % + 0.05 Ω, 0.015 % + 0.5 Ω

Ohms source

Ohms range

1.0 Ω to 400.0 Ω, 1.00 Ω to 400.00 Ω,

400.0 Ω to 1500.0 Ω,

1500.0 Ω to 4000.0 Ω

Accuracy (% of reading + counts)

0.015 % + 0.1 Ω, 0.015 % + 0.05 Ω,

0.015 % + 0.5 Ω, 0.015 % + 0.5 Ω

Resolution

0.00 Ω to 400.00 Ω

0.01 Ω

400.0 Ω to 4000.0 Ω

0.1 Ω

Millivolt measurement and source

Resolution

-10 mV to 75 mV

Range

0.01 mV

Accuracy (% of reading +counts)

0.015 % + 10 μA

New

Dimensions (HxWxD):

188.5 mm x 84 mm x 52.5 mm

Weight:

0.5 kg

Warranty: